[SOURce:]LIST[:SEGMent]:DEFine?

[:SEGMent]:DEFine?

Comments
Example

[:SEGMent]:SELect

Parameters
Comments
Example
162
HP E1340A Command Reference
[SOURce:]LIST[:SEGMent]:DEFine?
segment memory allocated for the segment currently selected by
SOURce:LIST:SEGMent:SELect
points in length, this query will always return 4096.
Executable when initiated: Yes
Coupled command: No
Related Commands:
*RST Condition: unaffected
Power-On Condition: Each waveform segment is defined to a
length of 4096
Querying the size of a waveform segment
LIST:SEL D
LIST:DEF?
[SOURce:]LIST[:SEGMent]:SELect <
for subsequent SOURce:LIST:SEGMent subsystem commands.
Parameter
Parameter
Name
Type
name
discrete
NONE selects no waveform segment
There are only 4 legal segment names: A, B, C, D. Alphabetic
character case (upper vs. lower) is ignored.
Executable when initiated: Yes
Coupled command: No
*RST Condition: unaffected
Power-On Condition:
Selecting a waveform segment
LIST:SEL A
returns the amount of the waveform
. Since all waveform segments are 4096
SOURce:LIST:SEGMent:SELect
Select waveform segment D
Query size of waveform segment D
name
selects a waveform segment
>
Range of
Values
A | B | C | D | NONE
SOURce:SEGMent:SELect NONE
Select waveform segment A
Default
Units
none