HP NonStop RDF J-series RVUs Management Manual page 431

For j-series and h-series rvus
Table of Contents

Advertisement

Cause
You have already added an extractor with an ATINDEX value of 0.
Effect
The ADD EXTRACTOR command fails.
Recovery
Review and revise your RDF configuration.
Master RECEIVER Record already exists
Cause
You have already added a receiver with an ATINDEX value of 0.
Effect
The ADD EXTRACTOR command fails.
Recovery
Review and revise your RDF configuration.
Maximum number of image trails already added
Cause
You have already added the maximum number of secondary image trails (255), and
cannot add more.
Effect
The command fails.
Recovery
No recovery action is possible; your RDF subsystem can only support 256 secondary
image trails.
Missing network master NETWORK record
Cause
No network record exists that corresponds to the network master subsystem.
Effect
RDF does not start.
Recovery
Add a network record to describe the network master subsystem.
MONITOR Record exists, use ALTER MONITOR
Cause
An ADD MONITOR command was issued when the configuration file already
contained a monitor record.
Effect
The command fails.
Recovery
No recovery is required if you want to use the existing monitor process as
configured. If you want to change any of the monitor's configuration options, however, enter
an ALTER MONITOR command that specifies those changes.
MONITOR record NOT found
Cause
The INFO command could not find a monitor record in the configuration file.
Effect
The command fails.
Recovery
Alter the configuration to include the monitor process.
Network options are only available with the RDF/IMPX product
Cause
You have attempted to specify configuration information for an RDF network, but
you do not have an RDF/IMPX license.
Effect
The configuration command fails.
Recovery
If you need to run in an RDF network, you need to obtain the RDF/IMPX license
and product.
NETWORK record can only be added into a networked subsystem
Cause
An ADD NETWORK command was entered but the RDF NETWORK parameter is
set OFF.
Effect
The ADD NETWORK command is rejected.
Recovery
Reconfigure RDF to have the RDF NETWORK parameter set ON.
Network record not found
Cause
The current RDF subsystem is configured in an RDF network, but a network record
has not been added.
Effect
Validation fails.
RDFCOM Messages