Additionally, the STATUS RDF display has been enhanced to identify which database volumes
are still being synchronized. That information is reported in the error column of the display. If
a volume is still being synchronized, its entry in the error column is sync. As soon as a volume
is successfully synchronized, its entry in the error column is blank. If an updater encounters an
error during synchronization, the associated entry in the error column is ****.
The following sample display shows that the updater process $MUP1 for the data volume
$DATA1 has successfully completed synchronization while the updater process $MUP2 for the
data volume $DATA2 is still doing the synchronization:
RDF Process
Name
------------------ ------ --------- --- ------- ------ ------------- ----- ----
Monitor
$MMON
Extractor (0)
$MEXT
Receiver
(0)
$MRCV
$DATA06 -> $DATA06 $MUP1
$DATA07 -> $DATA07 $MUP2
RTD Time
Pri Volume
185 $TRAILS
0:00 185 $TRAILS
0:00 185 $TRAILS
0:00 185 $TRAILS
1:59 185 $TRAILS
Determining When Online Database Synchronization Is Complete
Seqnce Rel Byte Addr Cpus
5
5
7110636
37
806912
37
806912
32
712704
Err
2: 3
1: 2
1: 2
1: 2
2: 3 sync
185