Info - HP NonStop RDF J-series RVUs Management Manual

For j-series and h-series rvus
Table of Contents

Advertisement

Now, suppose you issue a HISTORY command:
]HISTORY
In response, RDFCOM displays:
History:
ADD EXTRACTOR
START RDF
SHOW EXTRACTOR
ALTER EXTRACTOR PRIORITY 170
SHOW RECEIVER
ALTER RECEIVER PRIORITY 175
STATUS RDF
ALTER MONITOR PRIORITY 195

INFO *

HISTORY
INFO
The INFO command displays the current configuration parameter values from the configuration
file for the specified process or other object.
INFO {*
{IMAGETRAIL
{RDF
{MONITOR
{EXTRACTOR
{RECEIVER
{RDFNET
{NETWORK
{PURGER
{TRIGGER trigger-type }
{VOLUME *
{[VOLUME] $volume
*
displays the current configuration parameter values for the RDF global options, for all updater
volumes, and for all RDF processes.
[ATINDEX audittrail-index-num]
is an integer value from 0 through 15 identifying the TMF audit trail on the primary system
with which the particular RDF object is associated. 0 specifies the MAT. 1 through 15 specify
auxiliary audit trails AUX01 through AUX15, respectively.
You can use this option only with the EXTRACTOR, IMAGETRAIL, RECEIVER, and
[VOLUME] $volume variations of the INFO command.
For INFO EXTRACTOR, INFO IMAGETRAIL, and INFO RECEIVER commands, the default
is 0. If you omit this parameter, RDFCOM assumes you want to display information about
the designated object associated with the MAT.
For INFO VOLUME commands, this parameter is optional regardless of whether the updater
is associated with MAT or an auxiliary audit trail.
OBEYFORM
formats the INFO command output as command file text that can be executed by RDFCOM.
Before issuing the INFO command, you can designate the command file for this text by
specifying the file name in either:
The OUT option of the RDFCOM command that begins your interactive session
An OUT command issued during the session
If you do not specify a command file for the text, TACL supplies the name of its current
default output destination—usually the terminal from which you began your session.
206
Entering RDFCOM Commands
} [ATINDEX audittrail-index-num]
} [,OBEYFORM]
}
}
}
}
}
}
}
}
}