HP NonStop RDF J-series RVUs Management Manual page 381

For j-series and h-series rvus
Table of Contents

Advertisement

Effect
You cannot start the RDF subsystem.
Recovery
Purge all existing context and configuration files on the primary and backup system.
Then initialize the RDF subsystem.
763
Process incompatible with local system
Cause
The process reporting the error has determined that it has been installed on the wrong
operating system.
Effect
The process abends.
Recovery
Install the version of the RDF product that is compatible with the installed release
of the operating system.
764
Internal error - inconsistent NSA stop, [ANSI-object-type ANSI-name,
Partition partition-id,] file filename
ANSI-object-type
is the ANSI object type (for example, table, index, and so on.).
ANSI- name
is the ANSI name of the SQL/MX object that encountered the error.
partition-id
is the partition ID of the SQL/MX object that encountered the error.
filename
is the Guardian file name of the file that encountered the error.
Cause
The RDF monitor process detected an internal inconsistency regarding RDF's
understanding of an SQL shared access operation.
Effect
The monitor abends.
Recovery
This is an internal error. Contact your service provider.
765
Invalid audit record encountered [, type record-type ]
Cause
The updater process has sent an audit record to the disk process that is the wrong
version to the disk process that is in the wrong version. The record type is included in the
message if it is available.
Effect
The updater abends.
Recovery
This is an internal error. Contact your service provider.
766
Phase one part 1 database synchronization complete
Cause
The first part of phase one of a database synchronization operation has completed.
Effect
The extractor continues with processing the second part of phase one.
Recovery
This is an informational message; no recovery is required.
767
Phase one part 2 database synchronization complete
Cause
The second part of phase one of a database synchronization operation has completed.
Effect
The extractor continues with the third part of phase one.
Recovery
This is an informational message; no recovery is required.
RDF Messages