Connecting The Ac Power Cord To The Eps-C2 - Extreme Networks Summit X150 Series Hardware Installation Manual

Summit x150/x250e/x350/x440/x450/x450a/x450e/x460/x480/x650/x670 series
Hide thumbs Also See for Summit X150 Series:
Table of Contents

Advertisement

Chapter 7: Installing Summit External Power Supplies
Figure 250: EPS-C2 Connector Selector Switch
EPS-C2
Power Configuration Selector
2x9 Output
2x7 Output
Connector selector switch
After the EPS-C2 has been installed in a rack and the power supplies have been installed, do the
following to connect the redundant power cables:
1 Set the connector selection switch for either the 2X9 or 2X7 connectors.
2 Connect the keyed end (for the 2x7 connector cable, the end with the tab offset from the edge of the
connector pins) of the redundant power cord to the EPS-C2 chassis (see
side of the connector marked TOP is facing up.
3 Connect the other end of the redundant power cable (for the 2x7 connector cable, the end with the
key flush with the edge of the connector pins) to the Summit switch (see
side of the connector marked TOP is facing up.
Figure 251: Installing the Redundant Power Cord
Connect First
Redundant Power Output
Redundant Power
! See Manual
Repeat steps
2
and
3
4

Connecting the AC Power cord to the EPS-C2

After the redundant power cord is connected between the EPS-C2 and the switch, and an AC power
cord to the internal power supply of the switch is attached to a power source (see
Summit Family
Switches."), install the AC power cord to the power supplies in the EPS-C2 as follows:
304
Out
put
Redundant Power
Out
put
Redundant Power
! See Manual
! See Manual
! See Manual
! See Manual
to connect any additional redundant power cords.
Out
put
Redundant Power
Out
put
Redundant Power
! See Manual
! See Manual
! See Manual
Summit Family Switches Hardware Installation Guide
Figure
251). Verify that the
Figure
251). Be sure that the
Out
put
ESP-C2_02