Chapter 7: Installing Summit External Power Supplies

Installing an EPS-600LS Power Supply

To install an EPS-600LS unit into an EPS-C:
1 If necessary, remove a cover plate from a slot in the EPS-C.
2 Slide the EPS-600LS into an empty slot in the EPS-C (see
CAUTION
Be sure that empty slots in the EPS-C chassis are always covered by a cover plate when not in use.
The EPS-C is shipped with slots 2 and 3 covered and slot 1 open. Extreme Networks recommends that you
populate slot 1 with an EPS-600LS unit first, but this is not required. You can install EPS-600LS units into any of
the slots in the EPS-C. The installation sequence does not affect the performance of the power supply units, but
empty slots must be covered at all times.
Figure 235: Installing the EPS-600LS Unit in the EPS-C Chassis
! See Manual
O.T.P
DC OK
AC OK
3 Slide the unit completely into the chassis until the front of the EPS-600LS is flush with the surface of
the EPS-C (see
Figure
4 Align and tighten the captive screws to secure the EPS-600LS unit in place in the EPS-C
(see
Figure
236).
290
236).
Figure
235).
EPS-C_04A
Summit Family Switches Hardware Installation Guide