Dual-flame
stacked
burners
Care and Cleaning
Professional
All-Gas Range
The burner consists of three parts: the burner
base, burner head, and burner cap. The burner
head and burner cap can be lifted off, making
them easy to clean.
A CAUTION:
DO NOT OPERATE THE
BURNER WITHOUT ALL BURNER PARTS rN PLACE.
Surface burners should be cleaned routinely,
especially offer bad spillovers, which could clog
the slots and holes in the burner heads.
The electrode is located at the rear of each
burner. Do not attempt to disassemble or clean
around any burner white another burner is on. An
electric shock may result.
Burner Cap
Burner
Head
Burner Base
Electrode
Cleaning
Lift off burner parts only when cool. Wash in hot,
soapy water. You may use a plastic scouring pad
to remove burned-on food particles.
To remove burned-on food, soak the burner
heads in a solution of mild liquid detergent and
hot water for 20-30 minutes. For more stubborn
stains, use a plastic scouring pad or toothbrush.
tf the spill goes inside the burner head assembly,
wash it under running water and shake to
remove excess water.
After Cleaning
Before replacing the burner parts, shake out
excess water and then dry them thoroughly.
To replace the burner parts:
Make sure that the burner parts are replaced in
the correct locution.
1. Replace the burner head on top of the burner
base, making sure that the hole in the burner
head is properly aligned with the electrode
in the burner base. A small gap between the
base and head is normal.
2. Place the burner cap on top of the burner
head. Make sure that the burner cap is
properly seated on the burner head.
To remove the burner parts:
1. Turn all controls OFF before removing any
burner parts.
2. When cool, you may tift off the burner grates,
burner caps and burner heads for easier
cleaning. Do not remove the burner bases.
NOTE: The ZGP304 model has 2 different size
burners. Be sure to replace the burners in the
same location.
Burner cap properly seated
1
....
i
Burner cap not properlyseated
34