Restore Defaults (Configuration > Restore Defaults); Msl4048 Parallel Scsi Tape Drive Default Scsi Addresses - HP StorageWorks MSL2024 User's And Service Manual

Tape libraries
Hide thumbs Also See for StorageWorks MSL2024:
Table of Contents

Advertisement

Restore defaults (Configuration > Restore Defaults)
This option returns the Library to its original shipping configuration, leaving the settings necessary for
the RMI. Access to this feature requires the administrator password.
The following settings are reset:
SCSI addresses:
• MSL4048: For full-height tape drives the default SCSI address is 4. For half-height drives, the
default SCSI address for the bottom drive in each full-height drive bay is 4 and the default
SCSI address for the top drive is 5 as shown in
Figure 88 MSL4048 parallel SCSI tape drive default SCSI addresses
.
1. Tape drives with SCSI address 4
2. Tape drives with SCSI address 5
• MSL8048 and MSL8096: The default SCSI address for all tape drives is 4.
The Library will no longer recall drives that have been removed.
Master drive: reset to Drive 1 or the lowest numbered existing drive
Drive power: all drives powered on
Active slots: maximum possible
Library mode: Automatic
Loop: No
Event log levels and filter: continuous trace and all levels and filters active (for HP Service use only)
Barcode reader label length: 8
Barcode reader alignment: Left
Error recovery: On
Mailslot configuration: mailslot disabled
Auto clean: disabled
SNMP: disabled, but saved addresses do not change
E-mail notification: disabled, but configurations retained
The following settings are not reset:
Administrator password
Network settings (network is always enabled and the network addresses are retained)
Date and time
HP StorageWorks MSL2024, MSL4048, MSL8048, and MSL8096 Tape Libraries User and service
Figure
88.
guide
145

Advertisement

Table of Contents
loading

Table of Contents