Download Print this page

Threshold Value Operation - HP XP20000/XP24000 Reference Manual

Hp storageworks xp24000/xp20000 audit log reference guide (ae131-96085, may 2011)
Hide thumbs Also See for XP20000/XP24000:

Advertisement

Table 103 SIM Reporting Option Operation (continued)
Item
Service
Num. of Types

Threshold Value Operation

Example 1
user-name,xx,YYYY/MM/DD,HH:MM:SS.xx, 00:00,[Information],Threshold Value,Alter,Normal end,,,Seq.=xxxxx
+Type=7days
+{Mechanical error(Recovered,Unrecd.),Media error(Recovered,Unrecd.),
Read/Write error(Recovered,Unrecd.),Drive I/F error(Recovered,Unrecd.),
Controller hardware error(Recovered,Unrecd.),FC I/F error Port 0(Unrecd.),
FC I/F error Port 1(Unrecd.),Port 0 error(Unrecd.),Port 1 error(Unrecd.)}
={(150,60),(0,15),(150,30),(150,6),(150,6),6,6,12,12}
++PDEV=[HDDR00-01,HDDR00-02,(snip)],Num. of PDEVs=1152
Example 2
user-name,xx,YYYY/MM/DD,HH:MM:SS.xx, 00:00,[Information],Threshold Value,Error Reset,Normal end,,,Seq.=xxxxx
+PDEV=HDDR00-01
[Information]
Information function
Threshold Value
Threshold Value operation
Alter and Error Reset
Alter is the selected parameter for example 1 and Error Reset is the selected parameter for example
2. This operation uses the parameters shown in
Table 104 Parameters for Threshold Value Operation
Parameter
Alter
Error Reset
Normal end
The operation has ended normally.
Seq.=xxxxxx
Sequence number of log information (0000000000 to 4294967295)
Detailed Information
Detailed information displays for this operation, as shown in
Table 105 Threshold Value Operation (Example 1)
Item
Type
Mechanical error
(Recovered,Unrecd.)
Media error
(Recovered,Unrecd.)
Description
Report service level information as SIM.
ON: Report, OFF: Do not report
The number of information levels to be reported as SIM.
Description
Change the threshold of failed PDEV (physical device).
Indicates Error Reset.
Description
The period of time to acquire the result of threshold diagnosis using the read diagnosis
function.
7 days: 7 days, Total: Every operating days
The threshold of Mechanical error.
The threshold of Media error.
Table 104 (page
109).
Table 105 (page
109).
Threshold Value Operation 109

Advertisement

loading

This manual is also suitable for:

Storageworks xp20000Storageworks xp24000