Table 18: Recovery Processes (Continued)
Symptom
A device listed in
the DCC policy
cannot be accessed.
A policy that has
been created is not
listed by
secpolicyshow
command.
One or more
switches are
segmented from the
fabric.
Note:
For
instructions on
rejoining fabrics,
see the instructions
under
"Adding
Switches and
Merging Secure
Fabrics" on
page 101.
Secure Fabric OS Version 1.0 User Guide
Likely Problem
Port may be
Enter the switchshow command. If the port in
disabled.
question is disabled, enter the portenable command.
The new policy
Save or activate the policy changes by entering the
was not saved or
secpolicysave or secpolicyactivate
activated.
command.
Incorrect policy
Verify the correct policy name was used. Policy names are
name used.
case-sensitive and must be entered all uppercase.
SCC_POLICY is
Use the secpolicyadd command on the Primary FCS
excluding the
switch to add the switches to the SCC_POLICY.
segmented
switches.
Management
Make the Management Server services consistent across
Server services
all switches in the fabric by enabling or disabling the
on the segmented
same services.
switches are
inconsistent with
rest of fabric.
The segmented
Determine the status of the PKI objects by following the
switches are
procedure under
missing PKI
Certificates" on page 38. If any objects are missing,
objects.
replace as described under
Required" on page 39.
ISLs to the
Check the hardware connections and the port status for all
segmented
ISLs between the segmented switches and the fabric.
switches are
interrupted or a
port failure
occurred.
FCS policies on
If one or more switches are segmented without any FCS
the segmented
switches, enter the secmodeenable command on a
switches are not
segmented switch and specify an FCS policy that is
identical to the
identical to the FCS policy of the rest of the fabric. The
FCS policy of the
segmented switch or group of switches are automatically
fabric.
fastbooted.
If one or more switches are segmented with a Primary FCS
switch, modify the FCS policy as required until it is
identical to the FCS policy in the rest of the fabric.
Managing Secure Fabric OS
Recommended Actions
"Verifying Installation of the Digital
"Re-creating PKI Objects If
107