9. Determine which switches you want to designate as Primary FCS and Backup
10. Modify the SCC policy on the final Primary FCS switch (the one that will
11. Ensure that the final Primary FCS switch has the desired Secure Fabric OS
12. Verify that the fabric that contains the final Primary FCS switch has a
13. If fabrics are being rejoined after a segmentation, enter the
14. Physically connect the fabrics.
Secure Fabric OS Version 1.0 User Guide
FCS switches for the merged fabric, then modify the FCS policy for each
existing fabric to show these switches as the Primary FCS and Backup FCS
switches. Ensure that all the FCS policies are an exact match; they must list
the same switches, with the switches identified in the same manner and listed
in the same order.
If a fabric has become segmented with Secure Mode enabled but no FCS
switches available, enter the secmodeenable command to modify the
FCS policy. This is the only instance in which this command can be entered
when Secure Mode is already enabled.
succeed as the Primary FCS switch in the final merged fabric) to include all
switches that are being merged.
policy set, Zoning configuration, password information, and SNMP
community strings.
For information about managing Zoning configurations, refer to the HP
StorageWorks Fabric Zoning Version 3.1.x/4.1.x User Guide
(AA–RS26C–TE).
non-zero version stamp, by logging into the fabric and entering the
secstatsshow command. If this fabric does not show a non-zero version
stamp, modify a policy and enter either the secpolicysave or
secpolicyactivate command to create a non-zero stamp. Set the
version stamp of the other fabrics to zero by logging into each fabric and
entering the secversionreset command.
switchdisable and switchenable commands on each switch that
was segmented from the Primary FCS switch. For each ISL connected to the
segmented switch, enter the portdisable and portenable
commands on both ISL ports.
The fabrics automatically merge and the Secure Fabric OS configuration
associated with the Primary FCS switch that has the NON-zero stamp is kept.
Managing Secure Fabric OS