Failing Over The Primary Fcs Switch - HP StorageWorks MSA 2/8 - SAN Switch User Manual

Hp storageworks secure fabric os v1.0 user guide (aa-ru57a-te, june 2003)
Hide thumbs Also See for StorageWorks MSA 2/8 - SAN Switch:
Table of Contents

Advertisement

Creating Secure Fabric OS Policies
primaryfcs:admin> secpolicyfcsmove
Pos
Primary
=================================================
1
Yes
2
No
3
No
Please enter position you'd like to move from : (1..3) [1] 2
Please enter position you'd like to move to : (1..3) [1] 3
____________________________________________________
DEFINED POLICY SET
FCS_POLICY
Pos
Primary
__________________________________________________
1
Yes
2
No
3
No
____________________________________________________
primaryfcs:admin>
4. Enter the secpolicyactivate command.

Failing over the Primary FCS Switch

The secfcsfailover command is used to fail over the Primary FCS role to
the Backup FCS switch from which you enter the command. This can be used to
recover from events such as a lost Ethernet connection to the Primary FCS switch.
In addition to failing over the Primary FCS role, this command moves the new
Primary FCS switch to the top of the list in the FCS policy.
Note:
the FCS policy.
During FCS failover, all transactions in process on the current Primary FCS are
aborted.
56
Example, moving a Backup FCS switch from position 2 to position 3 in the
FCS list using interactive mode:
WWN
10:00:00:60:69:10:02:18
10:00:00:60:69:00:00:5a
10:00:00:60:69:00:00:13
WWN
10:00:00:60:69:10:02:18
10:00:00:60:69:00:00:13
10:00:00:60:69:00:00:5a
Disabling a switch or removing it from the fabric does not change the order of
DId
swName.
1
switch5.
2
switch60.
3
switch73.
DId
swName.
1
switch5.
3
switch73.
2
switch60.
Secure Fabric OS Version 1.0 User Guide