IP Phone Administrator Guide
Troubleshooting
Example 1
To turn two or more debug levels on at the same time, you add the value
associated with each level. For example,
Fatal Errors + Errors + Warnings = 1 + 2 + 4 = 7
log module linemgr: 7
log module user interface: 7
log module sip: 7
In the above example, fatal errors, general errors, and warnings are logged for the
line manager, user interface, and SIP call control modules.
Example 2
Functions and Info = 16 + 32 = 48
log module dis: 48
log module net: 48
log module snd: 48
In the above example, functions and general information are logged for the
display drivers, network, and sound modules.
Example 3
log module rtpt: 0
log module ind: 65535
In the above example, all debug levels are OFF for the Real Time Transport
module. All debug levels are ON for the indicator module.
You can set the Module/Debug Levels using the configuration files or the Aastra
Web UI.