Ac Adaptor - Toshiba Tecra M5 Maintenance Manual

Maintenance manual
Hide thumbs Also See for Tecra M5:
Table of Contents

Advertisement

2 Troubleshooting Procedures
Check 1
Compare the patterns in the hexadecimal error code to the tables below.

AC Adaptor

Error code
10h
11h
12h
13h
14h
1st Battery
Error code
22h
23h
24h
25h
2nd Battery
Error code
32h
33h
34h
35h
2-8
AC Adaptor output voltage is over 16.5V.
Advanced Port Replicator III Plus voltage is over 16.5V.
Current from the DC power supply is over 7.00A.
Current from the DC power supply is over 0.5A when there is no load.
Correction value of 0[A] is out of designed value.
1st battery discharge current over 0.5A when there is no load.
1st battery charge current is over 4.3A in charging.
Correction value of 0[A] is out of designed value.
1st battery charge current is over 0.3A in not charging.
Secondary battery discharge current is over 0.5A when there is no
load.
Secondary battery charge current is over 3.5A in charging.
Correction value of 0[A] is out of designed value.
Secondary battery charge current is over 0.3A in not charging.
[CONFIDENTIAL]
2.3 Power Supply Troubleshooting
Meaning
Meaning
Meaning
TECRA M5 Maintenance Manual (960-542)