Item
Description
7
PPM 1 failure
8
PPM 2 failure
9
Processor 2 failure
10
Power supply signal connector
interlock failure
1 1
Standby power good
12
Power supply fan module failure
13
System diagnostic
14
Online spare memory
15
Riser interlock
Node LEDs and internal health LED combinations
When the internal health LED on the front panel of the node illuminates either amber or red, the node is
experiencing a health event. Combinations of illuminated system board LEDs and the internal health LED
indicate node status.
Status
•
Amber = PPM has failed.
•
Off = PPM is operating normally.
•
Amber = PPM has failed.
•
Off = PPM is operating normally.
•
Amber = Processor has failed.
•
Off = Processor is operating
normally.
•
Amber = Power supply signal cable
is not connected.
•
Off = Power supply signal cable is
connected.
•
Green = Auxiliary power is applied.
•
Off = Auxiliary power is not applied.
•
Amber = One fan in this module has
failed.
•
Red = Multiple fans in this module
have failed.
•
Off = All fans in this module are
operating normally.
Refer to the HP Remote Lights-Out Edition
II User Guide.
•
Amber = Failover has occurred.
Online spare memory is in use.
•
Green = Online spare memory is
enabled, but not in use.
•
Off = Online spare memory is
disabled.
•
Amber = PCI riser assembly is not
seated.
•
Off = PCI riser assembly is seated.