GE MultiLink ML1200 Instruction Manual page 132

Managed field switch
Hide thumbs Also See for MultiLink ML1200:
Table of Contents

Advertisement

ACCESS USING RADIUS
Setting port control parameters (continued)
ML1200(auth)##
reauth port=1 status=enable period=300
Successfully set re-authentication parameter(s)
ML1200(auth)##
shoW-port reauth
Port
Reauth Status
=========================================
1
Enabled
2
Enabled
3
Enabled
4
Enabled
5
Enabled
6
Enabled
ML1200(auth)##
show-stats port=3
Port 3 Authentication Counters
authEntersConnecting
authEapLogoffsWhileConnecting
authEntersAuthenticating
authAuthSuccessesWhileAuthenticating
authAuthTimeoutsWhileAuthenticating
authAuthFailWhileAuthenticating
authAuthReauthsWhileAuthenticating
authAuthEapStartsWhileAuthenticating
authAuthEapLogoffWhileAuthenticating
authAuthReauthsWhileAuthenticated
authAuthEapStartsWhileAuthenticated
authAuthEapLogoffWhileAuthenticated
backendResponses
backendAccessChallenges
backendOtherRequestsToSupplicant
backendNonNakResponsesFromSupplicant
backendAuthSuccesses
backendAuthFails
ML1200(auth)##
trigger-reauth port=3
Successfully triggered re-authentication
ML1200(auth)##
7–8
Reauth Period (sec.)
300
3600
3600
3600
3600
3600
: 3
: 0
: 3
: 2
: 0
: 0
: 0
: 1
: 0
: 0
: 0
: 0
: 5
: 2
: 0
: 2
: 2
: 0
CHAPTER 7: ACCESS USING RADIUS
This command forces the
authentication period on port #1
every 5 minutes; all other ports are
force authenticated every hour as
indicated by the
command below.
MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL
show-port reauth

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents