CHAPTER 17: MISCELLANEOUS COMMANDS
17.5 Ping
17.5.1 Ping through the Command Line Interface
17.5.2 Ping through EnerVista Secure Web Management software
MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL
The
command can be used to test connectivity to other devices as well as checking
ping
to see if the IP address is setup correctly. The command syntax is:
ping <ipaddress> [count=<1-999>]
[timeout=<1-256>]
For example:
ML1200#
ping 3.94.248.61
3.94.248.61 is alive, count 1, time = 40ms
ML1200#
ping 3.94.248.61 count=3
3.94.248.61 is alive, count 1, time = 20ms
3.94.248.61 is alive, count 2, time = 20ms
3.94.248.61 is alive, count 3, time = 40ms
ML1200#
Many devices do not respond to
device responds or the network allows the ping packets to propagate.
The
command can be used from EnerVista Secure Web Management software to
ping
test connectivity to other devices as well as checking to see if the IP address is correct.
Select the Administration > Ping menu item to use ping.
As mentioned earlier, many devices do not respond to
the target device responds or the network allows ping packets to propagate.
or block
commands. Make sure that the target
ping
ping
ping
MISCELLANEOUS COMMANDS
commands. Make sure that
17–9
Need help?
Do you have a question about the MultiLink ML1200 and is the answer not in the manual?
Questions and answers