INSTALLATION
3.2
Connecting Ethernet Media
Note
3–2
The Multilink ML1200 Switches are specifically designed to support all standard Ethernet
media types within a single Switch unit. This is accomplished by using a family of different
Fiber Connectors which can be individually selected and configured per-slot. See Section
2.2 for a description of the PMs.
The various media types supported along with the corresponding IEEE 802.3, 802.3D,
802.3u, 802.3AB and 802.3z standards and connector types are as follows:
IEEE Standard
Fiber:
100BASE-FX
100BASE-FX
small form factor
small form factor
Copper:
10BASE-T
100BASE-TX
1000BASE-TX
mm = multi-mode, sm = single-mode
3.2.0.1 Connecting Fiber Optic ST-type, "twist-lock"
The following procedure applies to installations using a PM with ST-type fiber connectors.
This procedure applies to ports using a ML1200 module, MST-type port.
1.
Before connecting the fiber optic cable, remove the protective dust caps from
the tips of the connectors on the PM. Save these dust caps for future use.
2.
Wipe clean the ends of the dual connectors with a soft cloth or lint-free lens
tissue dampened in alcohol. Make certain the connectors are clean before
connecting.
One strand of the duplex fiber optic cable is coded using color bands at regular intervals;
you must use the color-coded strand on the associated ports at each end of the fiber optic
segment.
3.
Connect the Transmit (TX) port (light colored post) on the Multilink PM to the
Receive (RX) port of the remote device. Begin with the color-coded strand of
the cable for this first TX-to-RX connection.
4.
Connect the Receive (RX) port (dark colored post on the PM) to the Transmit
(TX) port of the remote device. Use the non-color coded fiber strand for this.
The LINK LED on the front of the PM will illuminate when a proper connection has been
established at both ends (and when power is ON in the unit). If LINK is not lit after cable
connection, the normal cause is improper cable polarity. Swap the fiber cables at the PM
connector to remedy this situation.
Media Type
Max. Distance
mm
2.0km (6,562 ft)
Fiber
sm Fiber
18.0km (95K ft)
mm Fiber
2.0km (6,562 ft)
sm Fiber
18.0km (95K ft)
mm Fiber
2.0km (6,562 ft)
sm Fiber
15 km
twisted pair
100m (328 ft)
twisted pair
100m (328 ft)
twisted pair
100m (328 ft)
MULTILINK ML1200 MANAGED FIELD SWITCH – INSTRUCTION MANUAL
CHAPTER 3: INSTALLATION
Fiber Connector
SC
SC
ST
ST
MTRJ, MLC
SLC
RJ-45
RJ-45
RJ-45
Need help?
Do you have a question about the MultiLink ML1200 and is the answer not in the manual?