Introduction; Abbreviations And Explanations - Carrier 19XRV Start-Up, Operation And Maintenance Instructions Manual

Hermetic centrifugal liquid chillers with pic iii controls 50/60 hz hfc-134a
Table of Contents

Advertisement

CONTENTS
(cont)
Page
Optional
Pumpout
System
Maintenance
.........
78
OPTIONAL
PUMPOUT
COMPRESSOR
OIL
CHARGE
OPTIONAL
PUMPOUT
SAFETY
CONTROL
SETTINGS
Ordering Replacement Chiller Parts .............
78
TROUBLESHOOTING
GUIDE
................
79-I 26
Overview
........................................
79
Checking
Display Messages
.....................
79
Checking
Temperature
Sensors
.................
79
RESISTANCE
CHECK
VOLTAGE
DROP
CHECK
SENSOR
ACCURACY
DUAL TEMPERATURE
SENSORS
Checking Pressure Transducers .................
79
COOLER
CONDENSER
PRESSURE
TRANSDUCER
AND OPTIONAL
WATERSIDE
FLOW DEVICE
CALIBRATION
TRANSDUCER
REPLACEMENT
Control
Algorithms
Checkout
Procedure
........
80
Control Test .....................................
81
Control Modules .................................
97
RED LED (Labeled
as STAT)
GREEN
LED (Labeled
as COM)
Notes on Module Operation
.....................
97
Chiller
Control
Module
(CCM)
...................
97
INPUTS
OUTPUTS
Replacing
Defective
Processor
Modules
........
98
INSTALLATION
Gateway Status
LEDs
...........................
99
DRIVE
STATUS INDICATOR
MS STATUS INDICATOR
NET A STATUS
INDICATOR
NET B STATUS INDICATOR
Physical
Data ...................................
100
APPENDIX
--
19XRV
LIQUlFLO
TM
2 ICVC
PARAMETER
INDEX ......................
127-135
INDEX ..........................................
136
INITIAL
START-UP
CHECKLIST
FOR
19XRV
HERMETIC
CENTRIFUGAL
LIQUID
CHILLER
....................
CL-I to CL-12
INTRODUCTION
Prior to initial start-up of the 19XRV unit, those involved in
the stall-up, operation,
and maintenance
should be thoroughly
familiar with these instructions
and other necessary
job data.
This book is outlined
to fmnili;uize
those involved
in the
stmt-up, operation and maintenance
of the unit with the control
system before
performing
stmt-up
procedures.
Procedures
in
this manual
;ue arranged
in the sequence
required
for proper
chiller start-up and operation.
This unit uses a microprocessor
control system.
Do not
shol_t or jumper between terminations
on circuit bo;uds or
modules; control or board failure may result.
Be aware of electrostatic
discharge (static electricity)
when
handling or making contact with circuit boards or module
connections.
Always
touch a chassis
(grounded)
part to
dissipate
body electrostatic
charge before working
inside
control centel:
Use extreme
c;ue when handling
tools near bo;uds
and
when connecting
or disconnecting
terminal plugs. Circuit
boards can easily be &_maged. Always hold boards by the
edges and avoid touching components
and connections.
This equipment
uses, and
can radiate,
radio
frequency
energy. If not installed
and used in accor&mce
with the
instruction
manu;fl,
it may cause
interference
to radio
communications.
It has been tested and found to comply
with the limits for a Class A computing
device pursuant to
Subpart J of Pall 15 of FCC Rules, which are designed
to
provide
reasonable
protection
against
such interference
when operated
in a commercial
environment.
Operation
of
this equipment
in a residential
area is likely
to cause
interference,
in which
case the usel: at his own expense,
will
be required
to take
whatever
measures
may
be
required to correct the interference.
Always store and transport replacement
or defective boards
in anti-static
shipping bag.
ABBREVIATIONS
AND EXPLANATIONS
Frequently used abbreviations
in this manual include:
CCM
-- Chiller Control Module
CCN
CCW
CW
ECDW
ECW
EMS
HGBP
I/O
ICVC
LCD
LCDW
LCW
LED
OLTA
PIC III
RLA
SCR
Sl
TXV
VFD
--
Carrier Comfort Network
--
Counterclockwise
--
Clockwise
--
Entering Condenser Water
--
Entering Chilled Water
--
Energy Management
System
--
Het Gas Bypass
--
Input/Output
--
International
Chiller Visual Controller
--
Liquid Crystal Display
--
Leaving Condenser Water
--
Leaving Chilled Water
--
Light-Emitting
Diode
--
Overload Trip Amps
--
Product Integrated Controls III
--
Rated Load Amps
--
Silicon Controlled Rectifier
--
International
System of Units
-- Thermostatic
Expansion Valve
--
Variable Frequency Drive
Words printed in all capital lettel_ or in italics may be
viewed on the International Chiller Visual Controller (ICVC)
(e.g., LOCAL, CCN, ALARM, etc.).
W_rds printed in both all capital letters and italics can also
be viewed on the ICVC and are parmneters (e.g., CONTROL
MODE,
COMPRESSOR
START
RELAY,
ICE
BUILD
OPTION, etc.) with associated values (e.g., modes, tempera-
tures, percentages, pressures, on, off. etc.).
W_rds printed in all capital lettel_ and in a box represent
softkeys on the ICVC control panel (e.g., _,
_,
[INCREASE[, _,
etc.).