INTRODUCTION

The Carrier VFD option Start-Up and Service Manual is intended
for trained and qualified service personnel and is to be used during
start-up, operation, and maintenance of Danfoss VLT FC102
series drives.

ABBREVIATIONS AND EXPLANATIONS

Frequently used abbreviations in this manual include:
DC
— Direct Current
HMI
— Human Machine Interface
IGBT
— Insulated Gate Bipolar Transistor
I/O
— Inputs/Outputs
IP
— Internet Protocol
LCP
— Local Control Panel
LEN
— Local Equipment Network
MCB
— Main Control Board
MDCIC — Multi-Drive Control Interface
MOV
— Metal Oxide Varistor
PCB
— Printed Circuit Board
PE
— Protective Earthing Conductor
PIC
— Product Integrated Control
PWM
— Pulse Width Modulation
STO
— Safe Torque Off
VFD
— Variable Frequency Drive

Required Publications

The Carrier VFD option Start-Up and Service Manual must be
used with the following manuals:
Latest version of the Danfoss VLT FC 102 and VLT paral-
lel AC Drives manuals as applicable.
Latest revision of the Start-Up, Operation, and Mainte-
nance Instructions for the 19XR with PIC 6 Controls.
Latest revision of the Controls Operation and Trouble-
shooting manual for 19XR with PIC 6 Controls.

Getting Assistance from Danfoss

For technical support on drives, contact Technical Support ex-
perts: 1-888-Danfoss (1-888-326-3677).
Before calling, have the following information available. Type
Code and Serial Number can be found on the Danfoss data name-
plate. See Fig. 1.
Image of drive nameplate including:
Carrier VFD Code (Carrier Part Number)
Danfoss Part Number / Type Code (T/C)
Danfoss Serial Number (S/N)
Images of cable connections, filters, resisters, fuses,
chokes, etc.
Alarms/warnings experienced
MCT 10 *.ssp file
For detailed repair procedures, refer to Danfoss VLT Drive
Service Manual MG94A502.
Carrier P/N:
SEE NOTE: 1
2
3
4
T/C: FC-102N560T4E54H2TXC7CXS009XAXBXCXXXXDX
P/N: 136L1239
S/N: 004902H121
560 kW / 750 HP
IN: 3x380-480V 50/60Hz 954/858A
7
OUT: 3x0-Vin 0-590Hz
Type 12 / IP54 Tamb. 40°C/104°F
Max Tamb. 55°C/131°F w/Output Current Derating
SCCR 100 kA at UL Voltage range 380-480V
Danfoss A/S
6430 Nordborg, Denmark
danfoss.com
Assembled by Danfoss for Carrier
U L
36UO E70524 IND. CONT. EQ.
C
US LISTED
UL Voltage range 380-480V
DANGER
See manual for special condition / mains fuse
Voir manuel de conditions spéciales / fusibles
8
NOTES:
1. Identifies product group and drive series. This should always start
with FC-102.
2. Drive Power Rating (N315, N355, N400, N450, N500, N560, N630,
N710, N800, N1M0).
3. Voltage Rating (T4 = 380-480V AC).
4. Enclosure Type: E54: IP54 (NEMA 12).
5. Drive type (H=6-pulse drive with RFI filter, P2=6-pulse parallel
drive with RFI filter).
6. S/N contains information related to Build date after the capital letter
(wwy, where ww is the week and y is the year; for example, 121 =
week 12, 2021.
7. IN = input voltage; OUT = output voltage.
8. Danger Electrical Symbol; 40 min indicates that for this size drive the
internal capacitors will have discharged 40 minutes after power has
been removed from the drive.
Fig. 1 — Sample Danfoss VFD Nameplate
3
5
6
990/890A
ASSEMBLED IN USA
089
40 min.