AT&T Merlin II Feature Module 2 System Manual page 73

Call management system
Hide thumbs Also See for Merlin II Feature Module 2:
Table of Contents

Advertisement

ADMINISTER A LINE
GROUP EXCEPTION
4-44 Selecting Exceptions
To administer a line group exception, follow these steps:
1 Press the function key for that exception and refer to the description and
instructions that follow this list. The exception message that appears
when each exception threshold is exceeded is also listed. A typical
example is
Group B - All Lines Busy > = XXX seconds
If you need more detailed instructions on administering exceptions, see
the information in "Administer Exceptions" under the heading,
"Instructions for Selecting Exceptions," earlier in this section.
2 Press a function key to administer another group exception, or press
to return to the Administration Menu.
Lines Busy (All Lines Busy). The all lines busy exception refers to the
[ F1 ]
number of seconds all lines in a line group are busy. If you turn on this
exception, CMS notifies you when the length of time all lines are busy meets
or exceeds the threshold you set. When all lines in a line group are busy,
incoming calls are blocked and callers receive a busy signal.
Prompt:
ALL LINES BUSY: ON/OFF?
Action:
1
Type on or off . Press
the current value.
If you want to enter threshold values, enter a number of
2
seconds (1 through 999) for each group. If you do not
want to activate this exception for a particular group, type
a hyphen.
3
Assign an alert number or enter a hyphen in the field to
the right of the slash.
4
Press
Exception:
Group X - All Lines Busy > = XXX seconds
HoldTime Maximum (Maximum Line Holding Time). The line holding
[ F2 ]
time refers to the number of seconds a line has been in use for a single call.
If you turn on this exception, the maximum line holding time exception
allows you to set an upper limit on the length of time a line is in use. CMS
notifies you when the length of time a line has been seized meets or exceeds
the threshold you set for its line group.
Prompt:
MAXIMUM HOLDTIME (minutes): ON/OFF?
B:
C:
1 Type on or off . Press
Action:
the current value.
2 If you want to enter threshold values, enter a number of
minutes (1 through 99) for each group. If you do not want
to activate this exception for a particular group, type a
hyphen.
3 Press
Exception:
Group X - Line XXXXX Hold Time > = XX minutes
( s / a ) A : _ / _ B : _ / _ C : _ / _ D : _ / _
(labeled "Next Field") to keep
[ F6 ]
(labeled "Enter Data") after the last field.
[ F8 ]
D:
[ F6 ]
(labeled "Enter Data") after the last field.
[ F8 ]
Line Group A:
(labeled "Next Field") to keep
[ F8 ]

Advertisement

Table of Contents
loading

Table of Contents