7
Characteristics and Specifications
U1211A Electrical Specifications

Voltage 1 ms peak hold specifications

Table 7-4 U1211A voltage 1 ms peak hold specifications

[1]

Current 1 ms peak hold specifications

Table 7-5 U1211A current 1ms peak hold specifications

[1]
124
Range
400 V
1000 V
Specified accuracy for changes is > 1 ms in duration. Use the null operation to zero out residual
offset before measuring the signal.
Range
40 A
400 A
1000 A
Specified accuracy for changes is > 1 ms in duration. Use the null operation to zero out residual
offset before measuring the signal.
Resolution
Accuracy
0.1 V
1.0% + 43
1 V
1.0% + 43
Resolution
Accuracy
0.01 A
2.0% + 70
0.1 A
2.0% + 43
1 A
2.0% + 43
[1]
Overload protection
1000 V
rms
[1]
Maximum overload
1000 A
rms