7
Characteristics and Specifications

U1213A Electrical Specifications

U1213A Electrical Specifications

The accuracy is given as ± (% of reading + number of least significant
digit) at 23 °C ± 5 °C, with relative humidity less than 80% R.H.

DC specifications

Table 7-17 U1213A DC accuracy ± (% of reading + number of LSD)
Function
[1]
DC voltage
[2]
DC current
[3][4][5][6][9]
Resistance
[3][7]
Diode/Continuity
134
Range
Resolution
4 V
0.001 V
40 V
0.01 V
400 V
0.1 V
1000 V
40 A
0.01 A
400 A
0.1 A
1000 A
1 A
400 Ω
0.1 Ω
4 kΩ
0.001 kΩ
40 kΩ
0.01 kΩ
400 kΩ
0.1 kΩ
4 MΩ
0.001 MΩ
40 MΩ
0.01 MΩ
Diode
0.001 V
Accuracy
0.2% + 3
1 V
0.5% + 3
1.5% + 15
1.5% + 5
2.0% + 5
0.3% + 3
0.6% + 3
2.0% + 5
0.5% + 2
Test current or burden
voltage
1000 V
rms
1000 A
rms
0.8 mA
80 µA
8 µA
727 nA
112 nA
112 nA
0.8 mA