Agilent Technologies U1701A Quick Start Manual

Dual display handheld capacitance meter
Hide thumbs Also See for U1701A:

Advertisement

Quick Links

Data Logger for Agilent
Handheld Capacitance
Meter
Quick Start Guide
Agilent Technologies

Advertisement

Table of Contents
loading

Summary of Contents for Agilent Technologies U1701A

  • Page 1 Data Logger for Agilent Handheld Capacitance Meter Quick Start Guide Agilent Technologies...
  • Page 2 Notices © Agilent Technologies, Inc. 2008-2009 Warranty Safety Notices No part of this manual may be reproduced in The material contained in this docu- any form or by any means (including elec- ment is provided “as is,” and is sub-...
  • Page 3: Table Of Contents

    Contents Contents Introduction System Requirements Agilent License Terms A. Hardware and Data Logger Installation Hardware Installation Data Logger Software Installation B. Equipment Setup and Connection C. Using the Data Logger Automatic - Continuous Mode Automatic - Up To x Count Mode Manual Mode D.
  • Page 4 Contents Data Logger for Agilent Handheld Capacitance Meter Quick Start Guide...
  • Page 5: Introduction

    For instrument set up and operation, please refer to the Agilent U1701A Dual Display Handheld Capacitance Meter User's and Service Guide, U1701- 90032 or Agilent U1701B Dual Display Handheld Capacitance Meter User's and Service Guide, U1701- 90055.
  • Page 6: System Requirements

    Introduction System Requirements Hardware Requirements Instrument Requirements: • U1701A/U1701B Dual Display Handheld Capacitance Meter • IR- USB Cable PC Requirements For best performance, ensure that your PC meets the following minimum requirements: PC Requirements Specification (Minimum) Processor Pentium® 1 GHz 32-bit (x86) processor or better Operating System Microsoft®...
  • Page 7: Agilent License Terms

    Introduction Agilent License Terms The following License Terms govern your use of the Licensed Materials unless you have a separate written agreement with Agilent, in which case, that written agreement will control and take precedence. License Grant. Agilent grants you a non- exclusive license to use one copy of the Licensed Materials.
  • Page 8 Introduction Ownership. The Licensed Materials are owned and copyrighted by Agilent or its third party suppliers. Your license confers no title to, or ownership in, the Licensed Materials and is not a sale of any rights in the Licensed Materials. Agilent's third party suppliers may protect their rights in the event of any violation of these License Terms.
  • Page 9 Licensed Materials by the applicable FAR or DFARS clause or the Agilent standard license agreement for the product involved. Contractor/Manufacturer is Agilent Technologies, Inc., 5301 Stevens Creek Blvd, Santa Clara, CA 95051 USA. Data Logger for Agilent Handheld Capacitance Meter Quick Start Guide...
  • Page 10: Hardware And Data Logger Installation

    Hardware and Data Logger Software Installation A. Hardware and Data Logger Installation Hardware Installation Make sure you have downloaded the Data Logger for Agilent Handheld N O TE Capacitance Meter application software from the Agilent Web site and install it to your PC before connecting the IR-USB cable to your PC. The IR-USB cable driver will be installed automatically as a pre-requisites prior to install the application software.
  • Page 11: Data Logger Software Installation

    Hardware and Data Logger Software Installation Data Logger Software Installation You may obtain the application software from Agilent Web site to install the Data Logger for Agilent Handheld Capacitance Meter. Prior to installing the Data Logger, ensure that your PC meets the minimum system N O TE requirements for installation and operation processes.
  • Page 12: Equipment Setup And Connection

    Equipment Setup and Connection B. Equipment Setup and Connection Connect the U1701A/U1701B Dual Display Handheld Capacitance Meter to a PC for instrument control: 1 Set up the communication parameters of the capacitance meter and the PC you are using. The default values for baud rate, parity, data bit, and stop bit in the capacitance meter are 9600, n, 8, and 1 respectively.
  • Page 13: Using The Data Logger

    Using the Data Logger C. Using the Data Logger The Data Logger software is a simple graphical user interface (GUI) that allows you to perform basic controls and measurements through a PC. The Data Logger allows data to be transferred from the meter to the PC via the IR- USB cable with data storing option.
  • Page 14: Automatic - Continuous Mode

    Using the Data Logger Automatic - Continuous Mode The Automatic- Continuos mode allows the data to be transferred to the PC automatically and continuously with a specific log interval. Procedures: 1 Click to select Automatic- Continuous in the logging mode list on the Data Logger window.
  • Page 15: Automatic - Up To X Count Mode

    Using the Data Logger Automatic - Up To x Count Mode The Automatic- Up to x count mode allows the data to be transferred to the PC at a specific logging count and log interval set by you. Procedures: 1 Click to select Automatic- Up to x count in the logging mode list on the Data Logger window.
  • Page 16: Manual Mode

    Using the Data Logger Manual Mode The Manual mode allows the data to be transferred to the PC manually. Procedures: 1 Click to select Manual in the logging mode list on the Data Logger window. In this mode, the logging count option and log interval option is disabled.
  • Page 17: Removing The Data Logger

    Hardware and Data Logger Uninstallation D. Removing the Data Logger The software can be removed either from the from the Windows Start menu or by the Windows Add/Remove Programs. Uninstalling from the Windows Start menu To remove the software from the Windows Start menu, proceed as follows: 1 Select Start (Windows taskbar) >...
  • Page 18: Uninstalling From The Windows Add/Remove Programs

    Hardware and Data Logger Uninstallation Uninstalling from the Windows Add/Remove Programs To remove the software by the Windows Add/Remove Programs, proceed as follows: 1 Select Start (Windows taskbar) > Control Panel to open the Control Panel window. 2 Double- click Add or Remove Programs. The Add or Remove Programs window will appear containing a list of currently installed programs.
  • Page 19 Always refer to Agilent web site for the latest revision. © Agilent Technologies, Inc. 2008-2009 Printed in Malaysia Third Edition, December 1, 2009 U1701-90033 A g i l e n t T e c h n o l o g i e s...