HP Cisco MDS 9020 - Fabric Switch Configuration Manual page 318

Cisco mds 9000 family cli configuration guide, release 3.x (ol-16184-01, april 2008)
Hide thumbs Also See for Cisco MDS 9020 - Fabric Switch:
Table of Contents

Advertisement

Upgrading the SSI Boot Image on an SSM
S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m
Log into the switch through the console port, an SSH session, or a Telnet session.
Step 1
Verify that the SSM is physically installed in the switch. If the module is not physically installed, insert
Step 2
it into the desired slot. Issue a show module command to verify the status of the module.
switch# show module
Mod
---
4
5
6
...
Note the slot number for later reference.
Verify the Cisco MDS SAN-OS release running on the switch and the location and name of the SSI boot
Step 3
image on the switch following the procedure described in the
page
Configure the SSI image boot variable to specify the SSI image to use when the SSM reloads.
Step 4
switch# config terminal
switch(config)# boot ssi bootflash:m9000-ek9-ssi-mz.2.1.1a.bin module 4
switch(config)# exit
switch#
Note
Caution
Issue the show boot command to display the current contents of the SSI boot variable.
Step 5
switch# show boot
sup-1
kickstart variable = bootflash:/boot-2-0-1-9
system variable = bootflash:/isan-2-0-1-9
sup-2
kickstart variable = bootflash:/boot-2-0-1-9
system variable = bootflash:/isan-2-0-1-9
Module 4
ssi variable = bootflash:/m9000-ek9-ssi-mz.2.1.1a.bin
Save the new boot variable configuration so the new boot image is used when the switch reboots.
Step 6
switch# copy running-config startup-config
Note
Reload the SSM to load the new boot image.
Step 7
switch# reload module 4
reloading module 4 ...
Cisco MDS 9000 Family CLI Configuration Guide
11-24
Ports
Module-Type
-----
-------------------------------- ------------------ ------------
32
Storage Services Module
0
Supervisor/Fabric-1
0
Supervisor/Fabric-1
11-20.
You can only specify one image for the SSI variable per module.
The SSI boot variable must reference the correct SSI boot image, otherwise the SSM fails to
initialize. If you do not correctly set the SSI boot variable, the SSM remains in the
power-down state after attempting to initialize three times.
If you do not save this configuration, it is lost on a switch reboot. In addition the SSM stays in
the power-down state if your switch is running Cisco MDS SAN-OS Release 2.1(1a) or earlier.
You must perform this procedure again to recover the SSI image boot variable configuration.
Chapter 11
Model
Status
DS-X9032-SSM
ok
DS-X9530-SF1-K9
active *
DS-X9530-SF1-K9
ha-standby
"Verifying the SSI Boot Image" section on
OL-16184-01, Cisco MDS SAN-OS Release 3.x
Managing Modules

Advertisement

Table of Contents
loading

Table of Contents