Appendix; Chassis And Module Power And Heat Values - Cisco 6509 - Catalyst Chassis Switch Installation Manual

Installation guide
Table of Contents

Advertisement

Chassis and Module Power and Heat Values

This appendix provides the power and heat numbers for the Catalyst 6500 series chassis and modules.
Unless otherwise noted, the information in the following tables is measured under fully-loaded
conditions (transceivers installed). Typical numbers are approximately 30 percent below the numbers
listed in these tables.
Module power is the output from the power supply (internal to the system). The AC-input power is the
Note
input from the outlet to the power supply. The percentage difference between the two values is the
efficiency of the power supply.
Table D-1
Power Requirements and Heat Dissipation—Chassis and Fan Trays
Model Number/
Module Type
Catalyst 6503 chassis
FAN-MOD-3 fan tray
FAN-MOD-3HS fan tray
Catalyst 6503-E chassis
WS-C6503-E-FAN fan tray
Catalyst 6504-E chassis
FAN-MOD-4HS fan tray
Catalyst 6506 chassis
WS-C6K-6SLOT-FAN fan tray
WS-C6K-6SLOT-FAN2 fan tray
OL-5781-04
Chassis and fan
trays—Table D-1
IP
phones—Table D-2
Supervisor
Engine—Table D-3
Modules—Table D-4
Module
Module
Power
Current (A)
(Watts)
0.80
34.00
2.98
125.16
1.37
57.54
1.43
60.06
0.71
30.00
2.00
84.00
A P P E N D I X
AC
DC
AC-Input
DC-Input
Power
Heat Diss.
Power
(Watts)
(BTU/HR)
(Watts)
43.00
145.00
46.00
156.45
534.28
168.23
71.93
245.62
77.34
75.08
256.38
80.73
37.48
128.00
40.00
105.00
359.00
113.00
Catalyst 6500 Series Switches Installation Guide
D
Heat Diss.
(BTU/HR)
156.00
574.49
264.11
275.68
136.88
386.00
D-1