3000 W AC-Input Power Supply
Table A-15 3000 W Power Supply Specifications (continued)
Specification
Power supply output
Front panel power connector
Output holdup time
Heat Dissipation
Front panel LEDs
INPUT OK
FAN OK
OUTPUT FAIL
42V OK
Weight
Catalyst 6500 Series Switches Installation Guide
A-36
Appendix A
Description
100/120 VAC operation
25.0 A @ +3.3 V
5 A @ +5 V
12 A @ +12 V
27.89 A @ +42 V
200/240 VAC operation
25.0 A @ +3.3 V
5 A @ +5 V
12 A @ +12 V
65.98 A @ +42 V
A two-pin male Molex connector is located in the
lower right corner of the power supply front panel. The
connector provides 42 VDC at a maximum of 17 A.
This connector provides power to the
WS-6509-NEB-UPGRD kit fan assembly through a
power harness also provided in the kit. A hinged
protective flap secured by a captive screw covers the
connector when it is not in use.
20 ms minimum
12,046 BTU/hour (approx.)
Green—Source AC voltage is OK. (Input voltage
is 85 VAC or greater.)
Off—Source AC voltage falls below 70 VAC, is
not present, or the power supply is turned off.
Green—Power supply fan is operating properly.
Off—Power supply fan failure is detected.
Red—Problem with one or more of the DC-output
voltages of the power supply.
Off—DC-output voltages within acceptable
margins.
Green—42 VDC is present at the fan power
connector.
Off—42 VDC is not present at the fan power
connector.
15.8 lb (7.2 kg)
Power Supply Specifications