Installing The Fan Assembly; Checking The Installation - Cisco 6509 - Catalyst Chassis Switch Installation Manual

Installation guide
Table of Contents

Advertisement

Chapter 4
Removal and Replacement Procedures

Installing the Fan Assembly

To install the new fan assembly, follow these steps:
Step 1
Hold the fan assembly with the fans facing to the right and the FAN STATUS LED at the bottom.
For the Catalyst 6509-NEB switch, hold the fan assembly with the fans facing down and the FAN
STATUS LED on the left. (See
assembly so that the handle is at the top of the assembly. (See
Place the fan assembly into the front chassis cavity so that it rests on the chassis, and then lift the fan
Step 2
assembly up slightly, aligning the top and bottom chassis guides.
Push the fan assembly into the chassis until the power connector seats in the backplane and the captive
Step 3
installation screws make contact with the chassis.
Tighten the captive installation screws.
Step 4
Note

Checking the Installation

To verify that the new fan assembly is installed correctly, follow these steps:
Listen for the fans; you should immediately hear them operating. If you do not hear them, ensure that
Step 1
the fan assembly is inserted completely in the chassis and that the faceplate is flush with the switch back
panel.
Verify that the FAN STATUS LED is green. If the LED is red, one or more of the fans are faulty.
Step 2
If after several attempts the fans do not operate or if you experience trouble with the installation (for
Step 3
instance, if the captive installation screws do not align with the chassis holes), contact a Cisco customer
service representative for assistance.
OL-5781-04
See
Figure 4-49
for the Catalyst 6503 and Catalyst 6503-E switches
See
Figure 4-50
for the Catalyst 6504-E switch
See
Figure 4-51
for the Catalyst 6506 and Catalyst 6506-E switches
See
Figure 4-52
for the Catalyst 6509 and Catalyst 6509-E switches
See
Figure 4-56
for the Catalyst 6513 switch
On the Catalyst 6509-NEB-A switch, fold the cable guide up, and tighten the two captive
installation screws at the top of the chassis. (See
Figure
4-53.) For the Catalyst 6509-NEB-A switch, hold the fan
Figure
Catalyst 6500 Series Switches Installation Guide
Removing and Installing the Fan Assembly
Figure
4-54.)
4-55.)
4-65

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ws-c6506Catalyst 6500 series

Table of Contents