Error codes

Category
Volume status
Unrecoverable

Examples

Example 1
Display example for Business Copy/Snapshot:
# pairvolchk -g oradb
pairvolchk : Volstat is P-VOL.[status = PAIR ]
Display example for Business Copy (specified with "-m grp" option):
# pairvolchk -g oradb
pairvolchk : Volstat is P-VOL.[status = PAIR CTGID = 1]
Display example for Continuous Access Synchronous:
# pairvolchk -g oradb
pairvolchk : Volstat is P-VOL.[status = PAIR fence = DATA
Display example for Continuous Access Synchronous Sync CTG:
# pairvolchk -g oradb
pairvolchk : Volstat is P-VOL.[status = PAIR fence = DATA CTGID = 2 MINAP = 2 ]
Display example for Continuous Access Asynchronous:
# pairvolchk -g oradb
pairvolchk : Volstat is P-VOL.[status = PAIR fence = ASYNC CTGID = 2 MINAP = 2 ]
MINAP displays the following two conditions (status) according to the pair status:
P-VOL: This shows the minimum in Active Paths on specified group in Continuous Access
Synchronous/Continuous Access Asynchronous.
S-VOL_ SSUS(SSWS): MINAP shows the result of the suspend operation that indicates whether the
remaining data on P-VOL was completely passed (synchronized) to S-VOL. If MINAP is "one", all
data is passed. Otherwise, all data is not passed from P-VOL.
NOTE:
If RAID F/W is not supporting the active paths, then the "MINAP" item is not displayed
as follows:
pairvolchk : Volstat is P-VOL.[status = PAIR fence = ASYNC CTGID = 2]
Example 2
Display example for Continuous Access Journal:
# pairvolchk -g oradb
pairvolchk : Volstat is P-VOL.[status = PAIR fence = ASYNC CTGID = 2 MINAP = 2 ]
MINAP displays the following two conditions (status) according to the pair status:
Error code
Error message
EX_ENQVOL
Unmatched volume
status within the
group
EX_EVOLCE
Pair volume
combination error
Recommended action
Confirm status using the pairdisplay command.
Make sure all volumes in the group have the
same fence level and volume attributes.
Confirm pair status using the pairdisplay
command, and change combination of
volumes.
Value
236
235
MINAP = 2 ]