HP StorageWorks P9000 Reference Manual page 89

Raid manager reference guide
Hide thumbs Also See for StorageWorks P9000:
Table of Contents

Advertisement

CL1-A / ef/ 0
0
CL1-A / ef/ 0
0
CL1-A / ef/ 0
0
CL1-A / ef/ 0
0
Output of the raidvchkscan command with -v offset option:
Bsize: Displays the data block size of Oracle I/O, in units of bytes.
STLBA: Displays the Start of LBA on a target volume for checking, in units of 512 bytes.
ENLBA: Displays the End of LBA on a target volume for checking, in units of 512 bytes.
Note: If STLBA and ENLBA are both zero, this means to check all blocks.
BNM: Displays the number of bits for checking regarding CHK-F2, in units of bits. If BNM is zero,
this means the checking for CHK-F2 is disabled.
Example 3: raidvchkscan command example with -v errcnt option
# raidvchkscan -p CL1-A -v errcnt
PORT# /ALPA/C TID# LU#
CL1-A / ef/ 0
0
CL1-A / ef/ 0
0
CL1-A / ef/ 0
0
CL1-A / ef/ 0
0
CL1-A / ef/ 0
0
Output of the raidvchkscan command with -v errcnt option:
CfEC: Displays the error counter for checking of block size validation.
MNEC: Displays the error counter for checking of CHK-F3 validation.
SCEC: Displays the error counter for checking of CHK-F1 validation.
BNEC: Displays the error counter for checking of CHK-F2 validation.
Example 4: raidvchkscan command example with the -v gflag option
# raidvchkscan -p CL1-A -v gflag
PORT# /ALPA/C TID# LU#
CL1-A / ef/ 0
0
CL1-A / ef/ 0
0
CL1-A / ef/ 0
0
Output of the raidvchkscan command with -v gflag option:
GI-C-R-W-S: Displays the flags for guarding as for the target volume.
I=E: Enabled for Inquiry command.
D: Disabled for Inquiry command.
C=E: Enabled for Read Capacity command.
D: Disabled for Read Capacity command.
R=E: Enabled for Read command.
D: Disabled for Read command.
W=E: Enabled for Write command.
D: Disabled for Write command.
S=E: Enabled for becoming the S-VOL.
D: Disabled for becoming the S-VOL.
PI-C-R-W-S: Displays the permission flags that show whether each mode flag can be changed to
enable or not.
I=E: "I" flag can be changed to enable.
D: "I" flag cannot be changed to enable.
C=E: "C" flag can be changed to enable.
1
2332
1
1
2
2332
1
2
3
2332
1
3
4
2332
1
4
Seq#
Num LDEV#
0
2332
1
0
1
2332
1
1
2
2332
1
2
3
2332
1
3
4
2332
1
4
<=Example of -v gflag option.
Seq#
Num LDEV#
0
2332
1
1
2332
1
2
2332
1
1024
1
1024
1
1024
1
1024
1
CfEC
MNEC
0
0
0
0
0
0
0
0
0
0
GI-C-R-W-S
PI-C-R-W-S R-Time
0
E E D D E
E E D D E
1
E E D D E
E E D D E
2
E E D D E
E E D D E
102400
9
102400
9
102400
9
102400
9
SCEC
BNEC
0
0
0
0
0
0
0
0
0
0
365
-
0
raidvchkscan
89

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xp p9500Storageworks p9500

Table of Contents