Option
Description
-find[g] conf
Displays the Port, target ID, LUN in horcm.conf image by using a special file (raw device file) provided
[MU#] [-g
via STDIN. If target ID & LUN are Unknown for the target device file, you must start HORCM without
name]
a description for HORCM_DEV and HORCM_INST, and should be described the shown the Port,
targetID, LUN for HORCM_DEV. This option can be used with the "-fx" option.
[-g name] specifies the group for "dev_group" on horcm.conf. If omitted, the group applies "VG" as
default.
The -findg option is used when displaying a LUN on the host view by finding a host group
(XP1024/XP128 Disk Array and later).
# cat /etc/horcmperm.conf | raidscan -find conf 0 -g ORA
HORCM_DEV
#dev_group dev_name port# TargetID LU# MU#
# /dev/rdsk/c23t0d0 SER = 61456 LDEV = 192 [ FIBRE FCTBL = 4 ]
ORA ORA_000 CL2-J 0 0 0
# /dev/rdsk/c23t0d1 SER = 61456 LDEV = 193 [ FIBRE FCTBL = 4 ]
ORA ORA_001 CL2-J 0 1 0
# /dev/rdsk/c23t0d2 SER = 61456 LDEV = 194 [ FIBRE FCTBL = 4 ]
ORA ORA_002 CL2-J 0 2 0
# /dev/rdsk/c23t0d3 SER = 61456 LDEV = 195 [ FIBRE FCTBL = 4 ]
ORA ORA_003 CL2-J 0 3 0
# ERROR [CMDDEV] /dev/rdsk/c23t0d7 SER = 61456 LDEV = 259 [ OPEN-3-CM ]
If the target device has shared an LDEV among multiple device files and an LDEV is displayed by
another target device already, then its target device is suppressed as a comment as shown below:
# ERROR [LDEV LINK] /dev/rdsk/c24t0d3 SER = 61456 LDEV = 195 [FIBRE FCTBL = 4]
If the target device does not have a valid MU#, then its target device is suppressed as a comment
as shown below:
# ERROR [INVALID MUN (2 < 1)] /dev/rdsk/c24t0d3 SER = 61456 LDEV = 195 [ OPEN-3 ]
If the target device is mixed with a different RAID TYPE, then its target device is suppressed as a
comment as shown below:
# ERROR [MIXING RAID TYPE] /dev/rdsk/c24t0d3 SER = 61456 LDEV = 195 [ OPEN-3 ]
-find sync[d]