List Of Diagnostic Tests; Example List Of Hardware Diagnostic Tests And Pass/Fail Criteria - HP StorageWorks P4000 User Manual

San solution
Hide thumbs Also See for StorageWorks P4000:
Table of Contents

Advertisement

List of diagnostic tests

This section shows a sample of the diagnostic tests that are available for the storage system.
For each test,
A description of the test
Pass / fail criteria
NOTE:
Available diagnostic tests are dependent on the storage system.
For VSA, only the Disk Status Test is available.
Table 31 Example list of hardware diagnostic tests and pass/fail criteria
Diagnostic test
Fan Test
Power Test
Temperature Test
Cache Status
Cache BBU Status
Disk Status Test
Disk Temperature Test
Disk SMART Health Test
Generate SMART logs (for
analysis contact Customer
Support)
Generate DSET Report &
Perc Event Logs (for ana-
lysis contact Customer
Support)
Generate Platform or HP
Diagnostic Report (for
analysis contact Customer
Support)
Table 31
on page 137 lists the following information:
Description
Checks the status of all
fans.
Checks the status of all
power supplies.
Checks the status of all
temperature sensors.
Checks the status of the
disk controller caches.
Checks the status of the
battery backed-up cache.
Checks for the presence
of all disk drives.
Checks the temperature of
all disk drives.
S.M.A.R.T. (Self-Monitor-
ing, Analysis, and Report-
ing Technology) is imple-
mented in all modern
disks.
Generates a drive health
report.
Generates a drive health
report.
Generates a drive health
report.
Pass criteria
Fan is normal
Supply is normal
Temperature is within
normal operating range
Cache is normal
The BBU is normal and
not charging or testing
All disk drives are present
The temperature is within
normal operating range
All drives pass health test
The report was success-
fully generated
The report was success-
fully generated
The report was success-
fully generated
P4000 SAN Solution user guide
Fail criteria
Fan is faulty or missing
Supply is faulty or missing
Temperature is outside
normal operating range
Cache is corrupt
The BBU is charging, test-
ing or faulty
One or more drives are
missing
The temperature is outside
normal operating range
Warning or Failed if one
or more drives fails health
test
The report was not gener-
ated
The report was not gener-
ated
The report was not gener-
ated
137