3.
Click Hardware Information Tasks, and select Refresh to monitor the ongoing progress.
Figure 126 Checking RAID rebuild status
.
For Dell 2950, NSM 2060, and NSM 4150 only
Use the RAID Setup tab to check the status of the RAID rebuild.
1.
Select the Storage category, and select the RAID Setup tab.
2.
Click the link on the tab to see the rebuild status.
You can view the RAID rebuild rate and percent complete.
3.
Click the link whenever you want to update the progress.

Return storage system to cluster

Return the repaired storage system to the cluster.
1.
In the navigation window, right-click the storage system, and select Add to Existing Management
Group.
2.
Select from the list the Group Name that the storage system used to belong to and click Add.
The storage system appears in the management group and the icon in the navigation window
flashes for a few minutes as it initializes.

Restarting a manager

Before proceeding, make sure that the storage system has finished initializing and is completely added
to the management group.