2.
Check the Status line on the Details tab.
1. Status line
Figure 65 Checking the storage system status on the Details tab
.
If status is Storage Server Overloaded
Wait up to 10 minutes and check the status again. The status may return to Normal and the storage
system will be resyncing.
If status is Storage Server Inoperable
Reboot the storage system and see if it returns to Normal, when it comes back up.
If these statuses recur
This may be an indication that the underlying hardware problem still exists.

Repairing a storage system

Repairing a storage system allows you to replace a failed disk in a storage system that contains
volumes configured for data protection levels other than Network RAID-0, and trigger only one resync
of the data, rather than a complete restriping. Resyncing the data is a shorter operation than a restripe.

Prerequisites

Volume must have Network RAID-10, Network RAID-10+1, Network RAID-10+2, Network RAID-
5, or Network RAID-6.
Storage system must have the blinking red and yellow triangle in the navigation window.