2
slotShow
Note
The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may
be in place. Refer to chapter 1, "Using Fabric OS Commands" and Appendix A, "Command
Availability" for details.
Operands
This command supports the following operands:
-p
-m
Examples
To display a basic view of all slots and their status:
812
VACANT
The slot is empty.
INSERTED, NOT POWERED ON
The blade is present in the slot but is turned off.
POWERING UP
The blade is present and powering on.
LOADING
The blade is present, powered on, and loading the initial configuration.
DIAG RUNNING POST1
The blade is present, powered on, and running the POST (power-on self-test).
DIAG RUNNING POST2
The blade is present, powered on, and running the pre-boot power on self
tests.
INITIALIZING
The blade is present, powered on, and initializing hardware components.
ENABLED
The blade is on and fully enabled.
ENABLED (SAS Virtualization Disabled)
The blade is on, but due to an incompatibility between the FOS image and the
SAS or Application image, the SAS Virtualization services are disabled. Only
applies to the FA4-18 blade.
DISABLED
The blade is powered on but disabled.
FAULTY
The blade is faulty because an error was detected.
UNKNOWN
The blade is inserted but its state cannot be determined.
In addition to the basic slot status view, displays the following information
about power consumption:
Direct current (DC) power consumption for each Blade in Watts.
Total alternate current (AC) Power Consumption in Watts.
AC efficiency, as a percentage of total and BTU.
Power efficiency in Watts/port and Watts/Gb.
In addition to the basic slot status view, displays the Brocade model name for
each blade.
switch:user> slotshow
Slot
Blade Type
ID
-----------------------------------
1
SW BLADE
51
2
SW BLADE
51
3
SW BLADE
55
4
SW BLADE
51
5
CORE BLADE
52
Status
FAULTY
DISABLED
ENABLED
DIAG RUNNING POST2
ENABLED
Fabric OS Command Reference