Ficoncupshow - Brocade Communications Systems 1606 Command Reference Manual

Brocade fabric os command reference v6.3.0 (53-1001337-01, july 2009)
Hide thumbs Also See for 1606:
Table of Contents

Advertisement

ficonCupShow

Displays FICON-CUP parameters for a switch.
Synopsis
ficoncupshow fmsmode
ficoncupshow modereg [bitname]
ficoncupshow MIHPTO
Description
Use this command to display FICON-CUP (Control Unit Port) parameters for a switch.
Note
The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may
be in place. Refer to chapter 1, "Using Fabric OS commands" and Appendix A, "Command
Availability" for details
Operands
This command has the following operands:
fmsmode
modereg
MIHPTO
Examples
To display the FMS mode for the switch:
To display the mode register for the switch:
Fabric OS Command Reference
53-1001337-01
Display the FICON Management Server (FMS) mode for the switch.
Display the FICON-CUP mode register. If no operand is specified, all mode
register bit settings are displayed. If a mode register bit name is specified,
then only the value of that bit is displayed. A value of 1 indicates that a given
mode register bit is set, and 0 indicates that it is not set.
The following operand is optional:
bitname
Displays the specified mode register bit as either set (1) or not set (0). Valid
values for bitname are:
POSC
Programmed offline state control
UAM
User alert mode
ASM
Active=saved mode
DCAM
Director clock alert mode
ACP
Alternate control prohibited
HCP
Host control prohibited
Displays the FICON-CUP missing interrupt handler primary timeout (MIHPTO)
value in seconds.
switch:user> ficoncupshow fmsmode
fmsmode for the switch: Enabled
switch:user> ficoncupshow modereg
POSC
UAM
ASM
DCAM
------------------------------
1
0
1
1
ACP
HCP
1
0
2
ficonCupShow