Brocade Communications Systems 1606 Command Reference Manual page 493

Brocade fabric os command reference v6.3.0 (53-1001337-01, july 2009)
Hide thumbs Also See for 1606:
Table of Contents

Advertisement

cost
Examples
To display the link costs for all ports on a switch:
To set the ISL cost on a port:
To display the new cost value on the same port:
To delete the cost value and reset to default:
To display the change:
See Also
interfaceShow, lsDbShow, topologyShow, uRouteShow, fcrRouterPortCost
Fabric OS Command Reference
53-1001337-01
Specifies the static cost of the link connected to the specified port. Valid
values are 0 to 65,535. Assigning a value outside this range will fail and
generate an error. A value of 0 removes the static cost and the port reverts to
its default link cost. If cost is not specified, the command displays the current
cost of the specified port.
switch:admin> linkcost
Slot
Interface
--------------------------------------
2
0
2
1
2
2
2
3
2
4
2
5
2
6
2
7
2
8
2
9
2
10
2
11 (E_PORT)
2
12
2
13
2
14
2
15
Type <CR> to continue, Q<CR> to stop:
switch:admin> linkcost 2/4 500
switch:admin> linkcost 2/4
Interface2/4
switch:admin> linkcost 2/4 0
switch:admin> linkcost 2/4
Interface2/4
Cost
500 (STATIC)
1000
500 (STATIC)
200 (STATIC)
1000
1000
1000
1000
1000
1000
1000
2000 (STATIC)
1000
1000
1000
1000
Cost
500 (STATIC)
Cost
1000
2
linkCost
463

Advertisement

Table of Contents