Portcfgdefault - Brocade Communications Systems 1606 Command Reference Manual

Brocade fabric os command reference v6.3.0 (53-1001337-01, july 2009)
Hide thumbs Also See for 1606:
Table of Contents

Advertisement

2

portCfgDefault

portCfgDefault
Restores the port configuration to factory default values.
Synopsis
portcfgdefault [slot/][ge]port
Description
Use this command to reset any special port configuration values to their factory defaults. This
command persistently disables ports capable of routing, which is the factory default value. You can
view the current port configuration using the portCfgShow command.
This command does not change the state of a port. To bring an E_Port go back online state, use
either switchDisable/switchEnable or portDisable/portEnable.
Note
The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may
be in place. Refer to chapter 1, "Using Fabric OS commands" and Appendix A, "Command
Availability" for details.
The Fabric OS port configuration commands are not supported on FCoE ports. Use fcoe --cfg to
configure FCoE ports.
Operands
This command has the following operands:
slot
port
Examples
To reset a port to factory defaults:
To reset a GbE port to factory defaults:
See Also
portCfgEport, portCfgGport, portCfgLongDistance, portCfgLport,
portCfgPersistentDisable, portCfgPersistentEnable, portCfgShow, portCfgSpeed,
portCfgTrunkPort
602
For bladed systems only, specify the slot number of the port to be reset to
default, followed by a slash (/).
Specify the number of the port to be reset to default, relative to its slot for
bladed systems. Use switchShow to list valid ports.
switch:admin> portcfgdefault 1/3
switch:admin> portcfgdefault 8/ge1
Fabric OS Command Reference
53-1001337-01

Advertisement

Table of Contents
loading

Table of Contents