Brocade Communications Systems 1606 Command Reference Manual page 477

Brocade fabric os command reference v6.3.0 (53-1001337-01, july 2009)
Hide thumbs Also See for 1606:
Table of Contents

Advertisement

When lfCfg is issued within a logical switch context, only the configuration regarding that switch
and the fabrics reachable from that switch is displayed. When the command is issued in a chassis
context the information for all chassis in the base fabric reachable from the current chassis is
displayed. Executing chassis-level commands requires chassis permissions. Refer to the
userConfig command for information on setting chassis user permissions.
Notes
The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may
be in place. Refer to chapter 1, "Using Fabric OS Commands" and Appendix A, "Command
Availability" for details.
This command is supported only on hardware platforms that are Virtual Fabric-aware and run
Fabric OS v6.2.0 or later. Refer to the Fabric OS Administrator's Guide for specific hardware
support.
You cannot use the portEnable command on logical ports. Use lfcfg with the --lislenable option to
re-enable disabled LISL ports on a logical switch.
Operands
This command has the following operands:
--show -cfg
--showall -cfg
--show -lisl
--showall -lisl
--lislenable
--help
Examples
To display logical fabric information for FID 2 in all chassis reachable from the base fabric.
Fabric OS Command Reference
53-1001337-01
Displays information for the fabric ID set by the context in all chassis
reachable from the base fabric.
Displays information for all fabrics in all chassis reachable from the chassis
context in which the command is executed. This option requires chassis
permissions.
Displays status information about the LISLs in the logical switch set by the
context.
Displays status information of all LISLs in the chassis. This option requires
chassis permissions.
-v
Displays, in addition to the LISLs, the physical ports on the base switch that
are associated with the LISL ports. This operand is optional with the -lisl
option.
Re-enables all LISLs in the fabric that were disabled because of some conflict
or error condition in the fabric. This command provides the option of manually
re-establishing the LISLs after the error condition has been resolved.
Displays the command usage.
switch:admin> lfcfg --show -cfg
------------------------------ Chassis: 1 ------------------------------
Chassis WWN: 10:00:00:05:1e:39:82:64
Number of Partitions: 2
Base switch domain: 1
Logical switch: 2
State: Online(1)
------------------------------ Chassis: 2 ------------------------------
Chassis WWN: 10:00:00:05:1e:0b:a4:5e
Number of Partitions: 2
Base switch domain: 2
Base switch: YES
Switch WWN: 10:00:00:05:1e:39:81:67
2
lfCfg
Fabric Id: 2
447

Advertisement

Table of Contents
loading

Table of Contents