Repair Array Drives

This function allows the online repair of array drives which show failed drives. After selecting this
menu option, StorCon displays a summary of all installed array drives and the number of array
drives which are in critical states (Figure 32). In the example in Figure 33 there is one array drive
in the Fail state. For example, the array drive is still operating but no longer redundant.
After pressing any key, StorCon displays a list of array drives which are candidates for online
automatic repair.
NOTE
Array drives that are in the Error state are very critical and have lost two or even more drives.
These array drives cannot be repaired with the Repair Array Drives function. In such critical cases
data integrity can no longer be maintained.
After selecting the array drive, StorCon displays the drive that failed. In the example in Figure 33 it
is the hard drive which forms logical drive 5.
After confirmation, the failed drive must be removed from the system and the new one configured
on the same ID and installed in the system. See Figure 34 and Figure 35.