Sign In
Upload
Manuals
Brands
Intel Manuals
Computer Hardware
SRCU32 - RAID Controller
Intel SRCU32 - RAID Controller Manuals
Manuals and User Guides for Intel SRCU32 - RAID Controller. We have
1
Intel SRCU32 - RAID Controller manual available for free PDF download: User Manual
Intel SRCU32 - RAID Controller User Manual (182 pages)
User Guide
Brand:
Intel
| Category:
Computer Hardware
| Size: 2.77 MB
Table of Contents
Table of Contents
3
1 Introduction and General Information
13
Intended Audience
13
RAID Levels
13
RAID 0 - Data Striping
13
Figure 1. RAID 0 - Data Striping
13
RAID 1 - Disk Mirroring/Disk Duplexing
14
Figure 2. RAID 1 - Disk Mirroring
14
Figure 3. RAID 1 - Disk Duplexing
14
RAID 4 - Data Striping with a Dedicated Parity Drive
15
RAID 5 - Data Striping with Striped Parity
15
RAID 10 - Combination of RAID 1 and RAID 0
16
Figure 5. RAID 5
16
Figure 6. RAID 10
16
Chaining
17
Configuring a Chaining Set Using Storcon
17
Levels of Drive Hierarchy Within the Intel RAID Controller SRCU32 Firmware
18
Level 1
18
Level 2
18
Level 3
18
Level 4
19
Transparency of Host Drives
19
Using CD-Roms, Dats, Tapes, Etc
20
2 Getting Started
21
What Is the Intel RAID Controller SRCU32 Firmware
21
Standard Firmware
21
RAID Hardware Installation and Setup
22
Minimum Hardware Requirements
22
Installing and Removing the SDRAM
22
Installing the SDRAM
22
Install the Intel RAID Controller SRCU32 in the Intel ® Server Board
23
Removing the SDRAM
23
Figure 7. Installing the SDRAM
23
Programming the FLASH Memory
24
SCSI Termination
24
Termination
24
Setting the Termination Mode of the Intel RAID Controller SRCU32
25
Configurable SCSI Parameters
25
Table 1. Hard Drive SCSI Parameters
25
Choosing a Configuration
26
How Many Hard Drives Should be Integrated into the Disk Array
26
What Level of Redundancy Is Needed
26
Table 2. RAID Level, Array Type, and Hard Drive Requirements
26
Are Hot Fix Drives Needed
27
Intel RAID Controller Hardware Features
27
Architecture Features (HW)
27
Table 3. RAID Level, Hard Drives, and Usable Storage Capacity
27
Table 4. Hardware Architecture
27
Environmental Characteristics
28
Hard Drive Connectivity (SCSI Specifics)
28
Supported Hard Drive Technology
28
Table 5. Environmental Specifications
28
Support for Non-Hard-Disk-Drive SCSI Devices (Non-Direct-Access Devices)
29
Table 6. SCSI Drive Standards
29
Array Roaming Compatibility
30
Number of Supported Devices
30
SCSI Connectors
30
LED Indicators
31
Function Check
31
Channel Mode
31
PCI Bus Clock
31
Jumpers
31
Table 7. Function Check
31
External LED Connectors
32
Terminator Power
32
Acoustical Alarm
32
Silencing the Acoustical Alarm in Storcon
32
Figure 8. External LED Connectors
32
Compatible Intel RAID Controllers
33
Optional RAID Features Implemented in the Intel RAID Controller SRCU32
33
Adapter Device Limitation Support
33
PCI Hot Plug
33
Table 8. Disk, Volume, and Array Limitations
33
Operational States of an Intel RAID Controller SRCU32 Firmware Disk Array
34
Operational States for RAID 4/5
34
Table 9. Operational States for RAID 4/5
34
Figure 9. Operational State Diagram for RAID 4/5
35
Methods for Hard Drive Replacement
36
Table 10. Additional Operational States
36
Table 11. Hard Drive Replacement Options
36
Intel RAID Controller SRCU32 Quick Start
37
Make an os Installation Diskette
37
Install the SDRAM
38
Install the Intel RAID Controller SRCU32 in the Intel Server Board
38
Use Storcon to Create a RAID Volume
38
Set the BIOS Boot Order
41
Install the Operating System (Choose from Windows 2000 or Red hat Linux 7.1)
42
Installing Windows 2000
42
Installing Red hat Linux 7.1
43
Alternative Method to Creating an Intel RAID Controller SRCU32 Installation Diskette
44
Windows NT
44
Windows 2000
44
SCO Unixware
44
How to Use Auto Hot Plug with SAF-TE
45
Setting up Auto Hot Plug
45
3 Installing Microsoft Windows NT or Windows 2000
47
Operating System Installation Procedures
47
Pre-Installation Requirements Checklist
47
Minimum Hardware Requirements
47
Minimum Software Requirements
48
Installing an Operating System Onto a RAID Volume or Single Disk
48
Windows 2000 / NT 4.0 Installation Procedures
49
Installing the os
49
Figure 10. Controller Settings
49
Installing an os Onto an IDE or SCSI Hard Drive Not Attached to the Intel RAID Controller SRCU32
50
Windows 2000 / NT 4.0 Installation Procedures
50
Upgrading an os (Windows NT 4.0 to Windows 2000) that Is Currently Installed on a RAID Volume or Single Disk
52
Installation to an Existing os
53
Installing Drivers for the Intel RAID Controller SRCU32
54
4 Installing Linux
55
Before You Begin
55
Available Drivers and Tools on the Intel RAID Controller SRCU32 Software Suite CD-ROM
55
Assumptions about Path Names
55
Table 12. Linux Path Names
55
General Installation Notes
56
Minimum Hardware Requirements
56
Minimum Software Requirements
56
Installing Red hat Linux 7.X on a RAID Volume (Host Drive)
56
Installing an Intel RAID Controller SRCU32 Onto an Existing Linux Server
57
Installation of Driver Sources from the Intel RAID Controller SRCU32 CD-ROM
57
GDT Driver Parameters
58
Reservation of SCSI Devices
58
Further Driver Parameters
59
Installation of Intel RAID Controller SRCU32 Storcon Monitoring Utility
60
Installation of Storcon from the Intel RAID Controller SRCU32 CD-ROM
60
Using Storcon Monitoring Utility
60
Remote Monitoring with the Intel SRCD Remote Access Service
61
SRCD Installation Instructions from the Intel RAID Controller SRCU32 CD-ROM
61
5 Installing Novell Netware
63
Pre-Installation Requirements Checklist
63
Minimum Hardware Requirements
63
Minimum Software Requirements
63
New Installation of Netware 4.2 and 5.1
64
New Installation of Netware 4.2 with the SRCRX.HAM Driver
64
New Installation of Netware 5.XX with the SRCRX.HAM Driver
64
Adding Intel RAID SRCU32 Controller(S), Drivers, And/Or Storcon to an Existing Netware Installation
65
Installing the Intel RAID Controller SRCU32 Driver Package
65
Installing the Intel RAID Controller SRCU32 Tools Kit Package
66
Configuring Tools for Remote Access
66
ASPI Support for Netware 4.2 and 5.1
66
Tips and Tricks
67
Optimize Data Throughput
67
Cache Memory Allocator out of Available Memory" in PCI-ISA Systems
68
Installing Netware 4.1 - Wrong Drive Name
68
Netware-Server Not Stable When under High Utilization
68
Intel RAID Controller SRCU32 and Non-ASPI Compatible Controllers
69
Last Status Information
69
Adding Additional Capacity after an Online Capacity Expansion
69
Notes on Arcserve
70
6 Installing Unixware
71
General Installation Notes
71
Minimum Hardware Requirements
71
Minimum Software Requirements
71
Installing the Intel RAID Controller SRCU32 as an Additional Controller
72
No Intel RAID Controller SRCU32 Has yet Been Configured for Unixware
72
An Intel RAID Controller SRCU32 Has Already Been Configured for Unixware
72
Installing an Operating System Onto a Host Drive or Single Disk
72
Installation of the RAID Software Suite for Unixware
73
Coordinates of SCSI Devices
73
Host Adapter Number (HA)
73
Unixware Bus Number, Target ID and LUN
74
Configuration Example
74
Table 13. Unixware Bus Number, Target ID, and LUN
74
Additional Information
75
7 Storage Console
77
Storcon Features
77
Storcon Is
77
Loading Storcon
78
Loading the Storcon Program under Netware
78
Loading Storcon on a Fileserver
78
Loading Storcon on a Workstation
78
Loading the Storcon Program under Windows NT/2000
79
Figure 11. Component Selection (Windows NT)
80
Figure 12. Component Selection (Windows 2000)
80
Uninstalling the RAID Software Suite
81
Figure 13. Add/Remove Programs (Windows 2000 Example)
81
Loading the Storcon Program under Windows 95/98
82
Loading Storcon under Linux
82
Loading Storcon under SCO Unixware
83
The Storcon Program
83
Select Interface
84
Figure 4. RAID 4
84
Figure 14. Select Interface
84
Table 14. Host Drive Types
84
Select Controller
85
Figure 15. Remote Machine
85
Figure 16. Select Controller
85
Monitor and Express / Advanced Setup
86
Monitor Menu
86
Express Setup / Advanced Setup Menus
86
Figure 17. Monitor and Express Setup / Advanced Setup Menu
86
Monitor Menu
87
View Statistics
87
Figure 18. View Statistics Menu
87
View Events
88
Figure 19. Physical Drive Statistics
88
Figure 20. Logfile Name
88
View Hard Drive Info
89
The Retries Counter
89
The Reassigns Counter
89
Figure 21. Controller Events
89
Figure 22. Hard Drive Information
89
The Grown Defects Counter
90
Last Status
90
Figure 23. Hard Drive Last Status
90
Save Information
91
Figure 24. Save Information
91
Express Setup
92
Configure Host Drives
92
Host Drive States
92
Figure 25. Screen Service Messages and Async. Events
92
Figure 26. Select Host Drive
93
Configure New Host Drive
94
Figure 27. Choose Type
95
Figure 28. Create Host Drive Confirmation
95
Figure 29. Hard Drive Capacity
95
Host Drive Options
96
Figure 30. Drive Status
96
Figure 31. Host Drive Options
96
Repair Array Drives
98
Figure 32. Array Drive Summary
98
Figure 33. Failed Hard Drive
98
Figure 34. Select Drive to Repair
98
Figure 35. Replace Hard Drive Prompt
99
Figure 36. Add Disk to Array Confirmation
99
Figure 37. Array Drive Summary
99
Figure 38. Array Drive Error State Dialog
99
Advanced Setup
100
Configure Controller
100
Controller Settings
100
Figure 39. Controller Settings Dialog
100
Table 15. Controller Settings
100
Firmware Update
101
Intelligent Fault Bus
101
Non-Intelligent Enclosures
102
Figure 40. Select Enclosure
102
Advanced Settings
103
Figure 41. Enclosure Slots
103
Figure 42. Advanced Settings Dialog
103
Table 16. Advanced Settings
103
Clear Log Buffer
104
Configure Physical Devices
104
Keyboard Commands
104
Figure 43. Select Physical Drive
104
SCSI Parameter / Initialize
105
Figure 44. Initialize Disk
105
Check Surface
106
Figure 45. Disk Initialization Confirmation
106
View Status/Defects
107
De-Initialize Disk
107
Lock/Unlock Disk
107
Enclosure Status
107
Figure 46. View Status/Defects
107
Table 17. View Status/Defects
107
Figure 47. Enclosure Status
108
Figure 48. Enclosure Slots
108
Figure 49. Block Diagram of a SAF-TE Subsystem
109
Configure Logical Drives
110
Keyboard Commands
110
Figure 50. Select Logical Drive
110
Figure 51. Select Physical Drive
110
Figure 52. Create Single Drive
111
Figure 53. Drive Size
111
Configure Array Drives
112
Keyboard Commands
112
Figure 54. Select Array Drive
112
Figure 55. Array Drive Menu
112
Change Drive Name
113
Expand Array Drive
113
Figure 56. Expand Array Dialog
113
Add RAID 1 Component
114
Replace Array Component
114
Remove RAID 1 Component
114
Remove Array Drive
114
Figure 57. Remove Drive Confirmation
114
Add Hot Fix Drive
115
In the Event of a Drive Failure
115
Remove Hot Fix Drive
116
Hot Fix Pool Access
116
Parity Verify
116
Periodic Parity Verify
116
Figure 58. Progress Information
116
Build/Rebuild Progress
117
Create New Array Drive
117
Figure 59. Create New Array Drive
117
Figure 60. Choose Type
118
Figure 61. Strip Size
118
Figure 62. Choose Build Type
118
Figure 63. Create Array Drive Confirmation
118
Figure 64. Drive Size Dialog
119
Figure 65. Array Drive Status
119
Notes on the Configuration of RAID 0, 1, 4, 5 and 10 Arrays Drives
119
Configure Host Drives
120
Change Drive Name
120
Swap Host Drives
120
Figure 66. Host Drive Configuration
120
Remove Host Drives
121
Split Host Drive
121
Merge Host Drives
121
Partition Host Drives
121
Overwrite Master Boot Code
121
8 Storage Console Plus
123
Introduction
123
Monitoring of the Whole Subsystem
123
Remote Configuration and Maintenance
123
The Storcon+ Controls
124
The Toolbar
124
Figure 67. Storcon+ Plus Toolbar
124
Table 18. Toolbar Icons
124
The Status Bar
125
Window Menu Commands
125
Help Menu Commands
125
Figure 68. Status Bar
125
Figure 69. Window Menu
125
Figure 70. Help Menu
125
File Menu Commands
126
View Menu Commands
126
The Chart Menu
126
Figure 71. File Menu
126
Figure 72. View Menu
126
Figure 73. Chart Menu
126
The Configuration Menu Commands
127
Figure 74. Physical Configuration Menu
127
Figure 75. Logical Configuration Menu
127
Figure 76. Refresh Rate Settings Dialog
127
Select Controller
128
Figure 77. Logical Configuration Menu
128
Table 19. Configuration Menu Refresh Settings
128
Figure 78. Select Controller
129
Figure 79. Sockets
129
Figure 80. Physical Configuration Icon
130
Figure 81. Example of a Physical Configuration and the Controller Settings
130
Physical Configuration Window
130
Figure 82. Controller Icon
131
Figure 83. Controller Settings Dialogs
131
Controller Configuration Settings
132
Change Settings
132
Save Information
132
Table 20. Controller Settings
132
Firmware Update
133
I/O Processors
134
Table 21. I/O Processor Icons
134
Figure 84. Processor Information
135
Channel Settings
136
Hot Plug: Add Disk
136
Rescan ID(S)
136
Direct Access Devices
137
Table 22. Direct Access Device Icons
137
Figure 85. Physical Drive Information
138
Synchronous Transfer
139
Table 23. Data Transfer Rates
139
The SCSI Parameter/Initialize
139
De-Initialize a Physical Disk
140
Disconnect
140
Lock / Unlock a Removable Disk
140
SCSI Read Cache / SCSI Write Cache
140
Tagged Queues
140
Non Direct Access Devices (Raw Devices)
141
Table 24. Non Direct Access Devices
141
Logical Configuration Window
142
Host Drives
142
Normal Host Drive
142
Array Drives
142
Figure 86. Logical Configuration
142
Table 25. Host Drive Icons
142
Table 26. Array Drive Icons
143
Logical Drives
144
Physical Drives
144
Table 27. Logical Drive Icons
144
Table 28. Physical Drive Icon
144
The Host Drive Information Window
145
Figure 87. Host Drive Information Window
145
The Array Drive Information Window
146
Figure 88. Array Drive Information Window
146
The Logical Drive Information Window
148
Figure 89. Logical Drive Information Window
148
Change the Name of a Drive
149
Remove a Host Drive
149
Create a New Host Drive
150
Figure 90. Create a New Host Drive
150
Parity Verify
151
Figure 91. Array Build Information Dialog
151
Figure 92. Parity Verify
151
Parity Recalculate
152
Progress Information
152
Figure 93. Parity Verify Progress Information
152
Expansion of an Array
153
Figure 94. Logical Configuration
154
Add a Hot Fix Drive
155
Figure 95. Add Hot Fix Drive
155
Remove a Hot Fix Drive
156
Hot Fix Pool Access
156
Add a RAID 1 Component (Mirror a Drive)
156
Remove a RAID 1 Component (Remove a Mirror Drive)
157
Figure 96. Add RAID 1 Component
157
Replace a Logical Drive
158
The Different States of an Array Drive
158
The Ready State
158
Figure 97. the Ready State
158
The Idle State
159
The Build / Rebuild State
159
The Fail State
160
The Error State
160
The Statistics Window
161
The Controller Events Window
162
Table 29. Event Window Icons
162
Storcon+ Help
163
Intel RAID Controller SRCU32 Service and Intel RAID Controller SRCU32 Mail
165
9 Getting Help
171
World Wide Web
171
Telephone
171
In U.S. and Canada
171
In Europe
171
In Asia-Pacific Region
172
In Japan
172
In Latin America
172
10 Regulatory and Certification Information
173
Product Regulatory Compliance
173
Product Safety Compliance
173
Product EMC Compliance
173
Product Regulatory Compliance Markings
174
Electromagnetic Compatibility Notices
175
FCC Verification Statement (USA)
175
ICES-003 (Canada)
176
CE Declaration of Conformity (Europe)
176
BSMI (Taiwan)
176
Warnings and Cautions
176
Warnings
176
Cautions
176
11 Appendix
177
BIOS Information
177
Background I/O's
177
BIOS Boot Messages
177
FLASH Memory Programming
179
Firmware Update Procedure Via XROM Storcon
179
Firmware Recovery
180
PCI Hot Plug Overview
181
Hot Insertion
181
Hot Removal
181
Advertisement
Advertisement
Related Products
Intel SRCU31A - Server RAID U3-1A Controller
Intel SRCU41L - RAID Controller
Intel SRCU42L - RAID Controller
Intel SRCU42X
Intel SRCU31
Intel SRCU42E
Intel SRCU31L
Intel SRCS16 - RAID Controller
Intel SRCSASPH16I - RAID Controller
Intel SRCZCR - RAID Controller Storage
Intel Categories
Motherboard
Computer Hardware
Server
Server Board
Desktop
More Intel Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL