  • Page 1 Hardware User’s Guide ® Intel RAID Controller SRCU42E J u n e 2 0 0 4 C76895-002...
  • Page 2 Intel may make changes to specifications and product descriptions at any time, without notice. Intel is a trademark or registered trademark of Intel Corporation or its subsidiaries in the United States and other countries.
  • Page 3: Safety Warnings

    WARNING: English Important Safety Instructions Read all caution and safety statements in this document before performing any of the instructions. See also Intel Server Boards and Server Chassis Safety Information on the Resource CD and/or at http:\\support.intel.com\support\motherboards\server\safecert.htm. SAFETY STEPS: Whenever you remove the chassis covers to access the inside of the system, follow these steps: 1.
  • Page 4 Lisez attention toutes les consignes de sécurité et les mises en garde indiquées dans ce document avant de suivre toute instruction. Consultez Intel Server Boards and Server Chassis Safety Information sur le CD Resource CD ou bien rendez-vous sur le site http:\\support.intel.com\support\motherboards\server\safecert.htm.
  • Page 5: Regulatory And Certification Information

    AVVERTENZA: Italiano PASSI DI SICUREZZA: Qualora si rimuovano le coperture del telaio per accedere all’interno del sistema, seguire i seguenti passi: 1. Spegnere tutti i dispositivi periferici collegati al sistema. 2. Spegnere il sistema, usando il pulsante spento/acceso dell’interruttore del sistema. 3.
  • Page 6 Regulatory Compliance Country Marking cULus Listing Marks USA/Canada ETL (NRTL) Mark USA/Canada CE Mark Europe FCC Marking (Class A) This device complies with Part 15 of the FCC Rules. Operation of this device is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation.
  • Page 7: Electromagnetic Compatibility Notices

    Consult the dealer or an experienced radio/TV technician for help. Intel is not responsible for any radio or television interference caused by unauthorized modification of this equipment for substitution or attachment of connecting cables and equipment other than those specified by Intel. The correction of interferences casued by such unauhtorized modification, substitution, or attachement will be the responsibility of the user.
  • Page 8 Preface ® This guide is the hardware reference and user’s guide for the Intel RAID Controller SRCU42E. It contains complete installation instructions and specifications . For information about how to configure the RAID Controller SRCU42E, and for an overview of the software drivers, see the Intel RAID Software User’s Guide.
  • Page 9 Safety Instructions Use the following safety guidelines to help protect your computer system from potential damage and to ensure your own personal safety. When Using Your Computer System As you use your computer system, observe the following safety guidelines: CAUTION: Do not operate your computer system with any cover(s) (such as computer covers, bezels, filler brackets, and front-panel inserts) removed: •...
  • Page 10 When Working Inside Your Computer Notice: Do not attempt to service the computer system yourself, except as explained in this guide and elsewhere in Intel documentation. Always follow installation and service instructions closely. 1. Turn off your computer and any peripherals.
  • Page 11: Table Of Contents

    Chapter 3 ® Intel RAID Controller SRCU42E Technical Reference Overview ......... . . 26 ®...
  • Page 12 Figures Install the Intel Portable Cache Module ....21 ® Inserting the Intel RAID Controller SRCU42E in a x8 PCI Express* Slot22 Terminating an Internal SCSI Disk Array....24 ®...
  • Page 13 Tables Intel® Raid Controller SRCU42E Features ....17 Target ID’s ......... 22 ®...
  • Page 14 Contents...
  • Page 15: Overview

    Chapter 1 Overview ® This section provides a general overview of the Intel RAID Controller SRCU42E . It consists of the following sections. • Section 1.1, “Overview,” page 15 • Section 1.2, “Features,” page 16 • Section 1.3, “Hardware,” page 17 Overview ®...
  • Page 16: Features

    • Advanced array configuration and management utilities • ® Battery backup for up to 72 hours with the 128 Mbyte Intel Portable Cache Module • Support for up to 14 SCSI drives per channel on storage system with SAF-TE enclosures (SCSI accessed fault-tolerant enclosures): 15 SCSI drives per channel for other configurations.
  • Page 17: Hardware

    Hardware ® You can install the Intel RAID Controller SRCU42E in a computer with a system board that has a x8 or x16 PCI Express slot. The following subsections describe the hardware configuration and configuration-on-disk. 1.3.1 RAID Controller Configurations Table 1-1 describes the features of the RAID Controller SRCU42E.
  • Page 18: Configuration On Disk

    1.3.2 Configuration on Disk ® Configuration on Disk saves configuration information both in NVRAM on the Intel RAID Controller SRCU42E and on the disk drives attached to the RAID Controller SRCU42E. If the RAID Controller SRCU42E is replaced, the new RAID Controller SRCU42E detects the actual RAID configuration from the configuration information on the drives.
  • Page 19: Hardware Installation

    SCSI uses the speed of the slowest device on the bus) • The Intel® Portable Cache Module (optional) or one 128-, 256-, or 512-Mbyte 200 MHz DDR1 ECC PC2700 DDR333 memory DIMM (your RAID Controller SRCU42E may come with a 128 Mbyte DIMM pre-installed) Intel strongly recommends using an uninterruptible power supply (UPS).
  • Page 20: Quick Installation

    DIMM, lining up the slot in the Intel® Portable Cache Module or DIMM with the alignment notch. d. Push the Intel® Portable Cache Module or DIMM firmly into the card. See letter A in Figure 2.1. e. Make sure the socket levers latch securely.
  • Page 21 Intel® Portable Cache Module only: Insert the screw included with the Intel® ® Portable Cache Module from the back of the Intel RAID Controller SRCU42E into the bracket on the Intel® Portable Cache Module. Figure 2.1 Install the Intel Portable Cache Module...
  • Page 22: Target Id's

    Set target identifiers (TIDs) on the SCSI devices. Each device in a channel must have a unique TID. Provide unique TIDs for non-disk devices (CD-ROM or tapes), regardless ® of the channel where they are connected. The Intel RAID Controller SRCU42E automatically occupies TID 7, which is the highest priority. The arbitration priority for a SCSI device depends on its TID.
  • Page 23 ® 7) Connect SCSI devices to the Intel RAID Controller SRCU42E. Use SCSI cables to connect SCSI devices to the RAID Controller SRCU42E. To connect the SCSI devices: a. Disable termination on any SCSI device that does not sit at the end of the SCSI bus.
  • Page 24 The BIOS Configuration utility prompt times out after several seconds. The second portion ® of the BIOS message displays the Intel RAID Controller SRCU42E number, firmware version, and cache SDRAM size. The numbering of the controllers follows the PCI slot scanning order used by the host system board.
  • Page 25: After You Have Installed The Raid Controller

    After You Have Installed the RAID Controller After installation, you must configure the RAID Controller SRCU42E and install the operating system driver. The Intel RAID Software User’s Guide instructs you about the configuration options and how to set them on your RAID Controller SRCU42E.
  • Page 26: Intel Raid Controller Srcu42E Technical Reference

    Chapter 3 ® Intel RAID Controller SRCU42E Technical Reference ® This chapter describes the characteristics of the Intel RAID Controller SRCU42E. This chapter contains the following sections: • Section 3.1, “Overview,” page 26 • ® Section 3.2, “Intel RAID Controller SRCU42E Characteristics,” page 28 •...
  • Page 27 ® Table 3-1Intel RAID Controller SRCU42E Headers and Connectors Connector Description Type Comments Write Pending Indicator 2-pin header Connector for enclosure LED to (Dirty Cache LED) indicate when data in the cache has yet to be written to the device. Optional.
  • Page 28: Intel ® Raid Controller Srcu42E Characteristics

    ® Intel RAID Controller SRCU42E Characteristics Table 3-2 shows the general characteristics for the RAID Controller SRCU42E . ® Table 3-2 Intel RAID Controller SRCU42E Characteristics Flash Serial LVD/SE Ultra320 SCSI SCSI SCSI EEPROM Signaling Data Transfers Features Termination 16-bit SE...
  • Page 29: Array Performance Features

    Array Performance Features Table 3-4 shows the RAID Controller SRCU42E array performance features: Table 3-4 Array Performance Features Specification Intel RAID Controller SRCU42E x8 PCI Express Host 2 Gbytes/second full duplex (4 Gbyte/second total) Data Transfer Rate theoretical Drive Data Transfer...
  • Page 30: Fault Tolerance

    Maximum dew point temperature: 32°C • Airflow must be sufficient to keep the heat sink temperature below 80°C ® The following parameters define the storage and transit environment for the Intel RAID Controller SRCU42E: • Temperature range: −40°C to +105°C (dry bulb) •...
  • Page 31: Safety Characteristics

    3.3.6 Safety Characteristics ® The Intel RAID Controller SRCU42E meets or exceeds the requirements of UL flammability rating 94 V0. Each bare board is also marked with the supplier’s name or trademark, type, and UL flammability rating. Since these boards are installed in a PCI bus slot, all voltages are below the SELV 42.4 V limit.
  • Page 32: Chapter A

    Chapter A Glossary of Terms and Abbreviations The electrical connection required at each end of the SCSI bus, composed of active voltage Active Termination regulation and a set of termination resistors. Ultra SCSI, Ultra2 SCSI, Ultra160 SCSI, and Ultra320 SCSI require active termination. BIOS Basic Input/Output System.
  • Page 33 This is the most common method (as opposed to differential SCSI, which uses a separate ground for each signal). A technology developed and used by Intel to improve data integrity, data transfer rates, and TolerANT noise immunity through the use of active negation and input signal filtering.

This manual is also suitable for: