3. On the front of the tower, switch on power. Verify that:
Power
switch
The ON/BUSYor BUSY indicators on the HP CD-ROM or
DVD-ROM drives go on.
The 4 indicator lights on the server module (illustrated
above) go on at the beginning of the power-on self-test.
When the Status indicator remains green and the SCSI
indicator is off, the server is ready for use. Depending on the
number of drives in use, this may take a few seconds to
five minutes.
The server auto-negotiates the link speed—10 or 100 megabits
per second—with other devices on the network.
4. Load a compact disc into the tray of a CD-ROM or DVD-ROM drive
(see page 2-6 or page 2-7). Verify that:
A CD-ROM drive's ON/BUSY indicator blinks and then
turns off shortly, and its DISC indicator goes on. If either
one flashes continuously, then either the disc is not
standard or there is a problem with the drive; refer to
chapter 10, "Troubleshooting".
A DVD-ROM drive's BUSY indicator blinks. If it remains
on continuously, then either the disc is not standard or
there is a problem with the drive; refer to chapter 10,
"Troubleshooting".
The server's SCSI indicator blinks during access. If it does
not, then verify your connections and cycle power (switch
power off and wait 10 seconds and then switch power on
again) to the server tower. If SCSI still does not blink, refer
to chapter 10, "Troubleshooting".
Repeat step 4 for all CD/DVD-ROM drives (including those in an
expansion tower).
Power indicator
Status indicator
SCSI indicator
Network indicator
Power indicator
DISC indicator
(not on J4152A)