SIS Configuration and Control
This section contains SIS communication details and SIS commands and responses for the
ShareLink Pro 2500. Topics in this section include:
•
Host Device Connection
•
SIS Overview
•
Command and Response Tables for SIS Commands
Host Device Connection
Use a connected computer running an SSH client such as PuTTY to send and receive SIS commands
and responses.
Use port 22023 for connection to the ShareLink Pro when using a control system. Enter the admin
username and password when prompted.
NOTE: The factory configured password for all accounts have been set to the device serial number
(passwords are case sensitive). Performing a
password to extron.
SIS Overview
Host and Device Communication
SIS commands consist of one or more characters per field. No special characters are required to begin or
end a command sequence. When the ShareLink Pro determines that a command is valid, it executes the
command and sends a response to the host device. All responses from the device to the host end with a
carriage return and a line feed
(CR/LF = ]), which signals the end of the response character string. A string is one or more characters.
Error Responses
When the ShareLink Pro receives an SIS command and determines that it is valid, it performs the
command and sends the corresponding response to the host device. If the command is determined
invalid or contains invalid parameters, the device returns an error response to the host. The error
response codes are:
= Invalid command
E10
= Invalid preset number
E11
= Invalid parameter
E13
= Not valid for this configuration
E14
= Invalid command for signal type
E17
= Busy
E22
= Privilege violation
E24
= Account does not exist
E35
Reset to Factory Defaults
ShareLink Pro 2500 • SIS Configuration and Control
(see page 7) sets the
59
Need help?
Do you have a question about the ShareLink Pro 2500 and is the answer not in the manual?