14. Moisture Monitors/Hygrometers
Moisture monitors or hygrometers allow the user to continuously monitor
moisture levels inside the glove box. Moisture monitors are normally placed
inside the main chamber to provide the best performance. Never operate a
transfer chamber vacuum evacuation on these sensitive hygrometers as
damage can occur.
Part #
5244900
5244901
5244800
5442200
5442201
15. Exterior Monitor Plumbing Kits (Part #'s below)
The exterior monitor plumbing kits provide attachment plumbing to oxygen or
moisture monitors outside the glove box. Note: The control and accuracy of
the oxygen and moisture monitors will be reduced due to the surrounding
ambient air rather than inert gas inside the glove box.
Part #
Descriptions
5442400
Plumbing Kit for Oxygen Monitor (0 to 10,000 ppm)
5442500
Plumbing Kit for Monitor/Hygrometer with pump (0 to 10,000 ppm)
16. Automatic Pressure Controller (for use with manual control Protector
Glove Boxes only)
The Pressure Controller provides the operator the convenience of
automatically regulating pressure and vacuum within the glove box main
chamber and transfer chamber. The end user can also automate the
evacuation/fill cycles up to 499 cycles for the main chamber and up to 199
cycles on the transfer chamber. The vacuum and pressure can be
automatically regulated between -5 to +5 inches of water gauge in the main
chamber and between 0 to -29 inches of mercury gauge in the transfer
chamber. See illustration below and figures in Chapter 3.
Part #
5238600
5238601
5239100
54
Descriptions
1-1000 ppm Moisture Monitor/Hygrometer (Factory Set at 1-
1,000 ppm, with three settings of 1-10 ppm, 1-100 ppm, and 1-
1,000 ppm) 100V/115V – 50/60 Hz
1-1000 ppm Moisture Monitor/Hygrometer (Factory Set at 1-
1,000 ppm, with three settings of 1-10 ppm, 1-100 ppm, and 1-
1,000 ppm) 230V – 50/60 Hz – International
0-100% Hand Held Digital Hygrometer with Temperature
Display; measures relative humidity and temperature
Moisture Meter Probe and Calibration Stand -80 to 0°C dew
point range or 0 to 6000 ppm (Display is in dew point only),
100-115V, 50-60 Hz
Moisture Meter Probe and Calibration Stand -80 to 0°C dew
point range or 0 to 6000 ppm (Display is in dew point only),
230V, 50-60 Hz
Electrical Configuration
100/115 Volts, 50/60 Hz operation
230 Volts, 50/60 Hz operation
Benchtop Bracket (required and ordered separate)
Product Service 1-800-522-7658
Used With
5244500, 01
5244900, 01

Advertisement

loading
Need help?

Need help?

Do you have a question about the Protector 50600 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

This manual is also suitable for:

Protector 50601Protector 50800Protector 50801