Download Print this page

Labconco Protector 50600 User Manual page 30

Controlled atmosphere glove boxes

Advertisement

C
h
a
p
t
e
r
4
C
h
a
p
t
e
r
4
P
e
r
f
o
r
m
a
P
e
r
f
o
r
m
a
P
r
e
c
a
u
t
i
o
P
r
e
c
a
u
t
i
o
Performance Features
The Protector Controlled Atmosphere Glove Box comes fully equipped with four
manual valves, pressure relief bubbler, and pressure monitoring of the main chamber
and transfer chamber. Manual Control models utilize analog gauges and Auto Pressure
Controller models utilize automatic control with digital LCD display gauges. Protector
Controlled Atmosphere Glove Boxes are available in single width fiberglass, single
width stainless steel, and double width stainless steel. The Protector Controlled
Atmosphere Glove Box is designed to meet the needs of the laboratory scientists
requiring an inert atmosphere for sensitive chemical operations. Labconco has
engineered the Protector Controlled Atmosphere Glove Boxes to meet the ISO 10648-2
Class 1 atmosphere leak specification. The Protector Controlled Atmosphere Glove
Box protects the technician from hazardous materials and protects valuable laboratory
materials from the effects of oxygen and moisture exposure. The Protector Controlled
Atmosphere Glove Boxes provide a leak tight environment for manufacturing and
chemical research procedures. See Figure 4-1 to refer to a detailed description of the
Protector Controlled Atmosphere Glove Box main performance features.
1. Fiberglass-lined models include:
 One piece molded fiberglass liner with clear acrylic inner and outer transfer
chamber doors.
 Performance tested to maintain oxygen levels as low as 0.4 ppm and
moisture levels as low as 2 ppm.
 Oxygen permeation <0.3 ppm/min per ISO 10648-2. Exceeds Class 1
conditions at <1.67 ppm/min.
 Illumination exceeds 120 foot candles.
2. Stainless steel-lined models include:
 Type 304 stainless steel liner with Type 304 stainless steel inner and outer
transfer chamber doors. Type 304 stainless steel front panel.
 Performance tested to maintain oxygen levels as low as 0.2 ppm and
moisture levels as low as 1 ppm.
26
:
:
n
c
e
F
e
a
t
u
n
c
e
F
e
a
t
u
n
s
n
s
r
e
s
a
n
d
S
r
e
s
a
n
d
S
Product Service 1-800-522-7658
a
f
e
t
y
a
f
e
t
y

Advertisement

loading
Need help?

Need help?

Do you have a question about the Protector 50600 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

This manual is also suitable for:

Protector 50601Protector 50800Protector 50801