Hexdump Mode - Printronix SL5000r User Manual

Rfid smart label and thermal printers
Hide thumbs Also See for SL5000r:
Table of Contents

Advertisement

Gothic Typeface
Controls which host command sets high speed printing.
Char 02 STX
Char 03 ETX
Char 09 HT
The factory default is Char 02 STX.
Graphic Chek Cod
Specifies the replacement character to print in place of any unprintable
character that is received from the host. Choose a hex character from 40
through FE. The character becomes the printer default when:
The printer is powered off and then powered on.
An SGEA command specifies to use the operator panel default.
The Graphic Chek Err parameter is disabled.
The range is 40 through F4, and the factory default is 60.
Graphic Chek Err
Allows overriding of the host setting for the SGEA (Set Graphic Error Action)
command. For more information about the SGEA command, refer to the
Coax/Twinax Programmer's Reference Manual .
Enable. The host setting for the SGEA used by the printer. If the SGEA
command is requested to stop on graphic errors, the printer will stop
when a graphic error is detected.
Disable. Ignores the SGEA command from the host. The printer does not
stop when an error is detected; instead, it substitutes the character
selected in the Graphic Chek Code parameter.
The factory default is Enable.

Hexdump Mode

Hexdump mode allows you to place the printer into the "hex dump" mode, in
which the printer outputs a hexadecimal data stream. The purpose of
hexdump mode is to see exactly what data is received by the printer, in order
to debug forms, for example.
When enabled, the hexdump mode translates all host interface data to its
hexadecimal equivalent, then prints the hex code and its printable symbol, if
one exists. Figure 5 shows a partial example of a hex dump.
After the printer enters hexdump mode, all characters it prints (including any
in the printer's input buffer) are printed in two forms: as a two-symbol
hexadecimal code and as the character's printable symbol (if it has one). A
non-printable code is printed as a period [.] symbol. Up to 16 characters can
be printed per line of hexdump printout. While the printer is in hexdump mode,
it does not act upon any control codes, other than to print their hexadecimal
equivalents.