3
Emulation Submenus
PA2
PA2 is only valid when the printer is offline and the coax SCS data stream is
active. This function displays the "PA2 ENABLED" message when the ↵ key is
pressed, and sends a special operator request to the host when the printer is
put back online.
NOTE: Selecting PA2 again ("PA2 DISABLED" appears on the operator
Page Rotation
This option rotates the physical IPDS page.
The options are 0, 90, 180, and 270.
The factory default is 0.
PDF Size Comp
This option is for compatability of the font size of the barcode printable data
field on the old build.
Enable. Matches the font size of the old build.
Disable. Uses the normal font size.
The factory default is Disable.
PGL Normal
This option determines whether PGL passes the text data in Normal mode
according to LP+ or whether PGL will print the text data itself.
LP+ Menu (the default). PGL will pass the text data to LP+ only in the
default setting state (6 LPI, default character set, and font attribute).
PGL Menu. PGL will always print the text data itself.
PI Slew Range
You can specify how many lines the paper will feed.
15. A paper slew of 1-15 will move 1-15 lines. A paper slew of 0 will move
1 line.
16 (the default). A paper slew of 0-15 will move 1-16 lines.
Position Aft FF
Allows you to select the location of the print position after a Form Feed
command is sent.
Off (the default). Sets the printer to print at position 2 of the first print line
on the next form.
On. Sets the printer to print at print position 1 of the first print line on the
next form.
222
panel) or selecting PA1 will reset the pending PA2 function.