2.
Plug one end of the null modem serial cable into the serial port on the enclosure (FIG. 11)
FIG. 11
Attach null modem serial cable to serial port
3.
Plug the other end of the serial cable into the serial port on the serial
controller/device.
4.
Open the serial communication software and set the port settings to match
the Optima default settings (see table to the right). In addition to the default
baud rate of 9600, Optima enclosures support baud rates of 19200, 38400,
and 57600. The settings on the PC serial communication software and the
enclosure must correspond to each other. If a change is required to make
them match, changing the PC's settings is preferable. If you decide to
change the enclosure's settings instead, use XNConnect (see the Help file).
Caution: To avoid system damage, follow the power-up sequence on page 34. We recommend
attaching all power cords to a surge protector and/or AC line conditioner.
5.
If not already on, apply power first to the Optima enclosure and then to the source and destination
devices (see "Applying Power & Startup" on page 34).
6.
Set up and run the desired method of control:
7.
Execute a test switch to ensure the Optima is working properly
(see "Executing a Test Switch" on page 37).
30
®
NetLinx
compatible controller
APControl 3.0
– Install and open the program (located on the AMX AutoPatch CD).
Follow the setup wizard, which will discover the system's configuration information
and open the APControl Launchbar.
Terminal emulation (HyperTerminal)
that the settings match those in the Optima Serial Port Settings table above (if COM port
settings do not match, enter the applicable values from the Optima table).
Click OK. A short splash screen appears.
– Contact your AMX representative.
– Open the program, select the COM port, and check
Optima
Serial Port Settings
Baud
9600
Data Bits
8
Parity
None
Stop Bits
1
Flow Control
None
Optima Instruction Manual